D9412GV4/D7412GV4/D7212GV4
Keypad Programming of RPS PHONE #
D1255
1.
2.
3.
4.
5.
D1260
1.
2.
3.
4.
5.
6.
RPS Modem Speed
Default:
Selection:
Select the baud rate for RPS-to-control panel communication when using a PSTN connection.
3.9

Miscellaneous

Duress Type
Default:
Selection:
0
1
Bosch Security Systems, Inc.
Refer to Section 2.5.1 Keypad Programming Menu, page 12 to access Keypad Programming
and navigate to the RPS PARAMETERS option. Press [ENT]. The keypad shows the RPS
PASSCODE option and the currently configured passcode.
Press [NEXT] to advance to the RPS PHONE NUMBER option.
The keypad shows the currently configured phone number. Press [ENT] to edit the phone
number.
The [PREV] button acts as a [Backspace] key. Press [PREV] to delete the characters of
the phone number, and then enter the new phone number.
Press [ENT] to save the phone number. When the keypad reads PARAMETER SAVED,
your selection has been configured.
Refer to Section 2.5.1 Keypad Programming Menu, page 12 to access Keypad Programming
and navigate to the RPS Parameters option. Press [ENTER]. The keypad shows the RPS
Passcode and the currently configured passcode.
Press Phone Number softkey.
The keypad shows the currently configured phone number.
Press the Edit softkey to change the phone number.
The Pause and DT Detect (Dialtone Detect) softkeys enter special characters. The
Backspace softkey allows you to erase characters. The Clear softkey allows you to clear
the entire phone number. The [COMMAND] and [ENTER] keys allow you to enter an * or a
#. Use the softkeys, the number buttons, and the [COMMAND] and [ENTER] keys on the
keypad to enter the new phone number.
Press [ENT] to save the phone number. When the keypad reads Parameter Saved, your
selection has been configured.
1200
300, 1200, 2400
0
0, 1, 2, or 3
Do not send a duress event with any passcode.
Increase the last digit by 1 to generate an alarm. For example, if the
passcode is 6123, 6124 activates a duress alarm.
If the last digit of the passcode is 0, a duress alarm occurs when the
user enters 1 as the last digit of the passcode.
If the last digit of the passcode is 9, a duress alarm occurs when the
user enters 0 as the last digit of the passcode.