Bosch D9412GV4 Program Entry Manual page 82

Table of Contents

Advertisement

82
en | Panel and Area Wide Parameters
Determines whether any of the areas and doors are included in the scope of this keypad for
viewing status, arming or disarming, and controlling doors from the keypad.
Keypad Programming of CC# Scope
D1255
1.
2.
3.
4.
5.
D1260
1.
2.
3.
4.
5.
When the keypad reads Parameter Saved, your selection has been configured.
CC# Passcode Follows Scope
Default:
Selection:
Yes
No
Use this program to determine if this keypad follows CC# Scope or if it only arms or disarms
the area to which it is assigned. The user must have authority enabled in L## Passcode Arm
and L## Passcode Disarm. This feature does not affect the Function List arming and
disarming commands.
F.01U.218.312 | 04 | 2012.03
Refer to Section 2.5.1 Keypad Programming Menu, page 12 to access Keypad Programming
and navigate to the COMMAND CENTER option.
Press [ENT]. The CC NUM 1 – 16 option shows.
Enter the keypad number you wish to configure and press [ENT]. The keypad reads CC#
SCOPE, and then the current configuration (for example, PANEL WIDE).
To change the configuration, press [ENT] when the current configuration shows, and
then press [NEXT] or [PREV] to scroll through the options, as listed in Section CC#
Scope, page 81.
When the keypad reads the desired configuration option, press [ENT] to select it. When
the keypad reads PARAMETER SAVED, your selection has been configured.
Refer to Section 2.5.1 Keypad Programming Menu, page 12 to access Keypad Programming
and navigate to the Command Center option.
Press [ENTER]. The CC Num 1 – 16 option shows.
Enter the keypad number you wish to configure and press [ENT]. The keypad reads CC#
Scope, and then the current configuration (for example, Panel Wide).
To change the configuration, press the Edit softkey, and then press the Next or Previous
sofkeys to scroll through the options, as listed in Section CC# Scope, page 81.
When the keypad reads the desired configuration option, press the Save softkey to select
it.
Yes
Yes or No
Master Arming allows a user to change the armed state of the areas
within the scope of this keypad. If the areas in the scope are already at
the intended armed state, they remain in that state.
If the area to which this keypad is assigned is armed, entering a
valid passcode disarms this area and all other areas assigned to
the scope of this keypad.
If the area to which this keypad is assigned is disarmed, entering a
valid passcode arms this area and all other areas assigned to the
scope of this keypad.
Restricts the scope of the keypad to the Area programmed in CC# Area
Assign for the purpose of executing L## Passcode Arm and L##
Passcode Disarm only.
Program Entry Guide