HISTory:POWer[:HISTogram]? <supply>[,MIN|MAX]
Parameters
Returned Data
Comments
Error Conditions
Reset Condition
Related
Commands
Chapter 3
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
HISTory:POWer[:HISTogram]?
<supply>. Ten values are returned for the amount of time the <supply>'s power
spent in ten different power ranges. Those power ranges can be queried with the
and
optional parameter. The units of the time values returned are HOURs by
MAX
default, but can be changed with the
returned for power ranges queried with the
values in milliwatts.
Name
Type
Range
<supply>
enum. P5, P12, N12, P24,
N24, N5PT2, N2,
TOTal
optional
enum. MIN, MAX
parameter
Type
<range1>
int32
<range2>
int32
<range3>
int32
<range4>
int32
<range5>
int32
<range6>
int32
<range7>
int32
<range8>
int32
<range9>
int32
<range10>
int32
returns 10 time values for +5V supply.
HIST:POW? P5
HIST:POW? P5,MAX
each power range in milliwatts.
The following table lists the most common error conditions and causes. Error
numbers and corresponding messages can be found using
Number
Message
-224
"Illegal Parameter"
-109
"Missing Parameter"
-311
"Memory error"
-221
"Settings Conflict"
A *RST has no effect on the HISTory subsystem.
HISTory:POWer:MAXimum?, HISTory:RESet:POWer, HISTory:UNITs[:TIME]
<supply> returns the histogram data held for the
HISTory:UNIT[:TIME]
or
MIN
MAX
Default
none
Selects the power supply whose power
histogram is desired. P5 is +5 Vdc
supply, N12 is -12 Vdc supply, etc.
none
Returns the maximum or minimum of
the power range in milliwatts.
Range
Default
0-2147483647
none
0-2147483647
none
0-2147483647
none
0-2147483647
none
0-2147483647
none
0-2147483647
none
0-2147483647
none
0-2147483647
none
0-2147483647
none
0-2147483647
none
returns 10 values representing the maximum power for
Probable Cause
The <supply> or optional parameter not correct.
The <supply> parameter was omitted.
The historical data's memory is not available.
The power supply doesn't support power
measurements.
Programming the Enhanced Monitor
MIN
command.The units
parameters are integer
Description
Description
lowest power range.
second power range.
third power range.
fourth power range.
fifth power range.
sixth power range.
seventh power range.
eighth power range.
ninth power range.
highest power range.
query.
SYSTem:ERRor?