Status:questionable:blower:enable <Mask> Status:questionable:blower:enable - Agilent Technologies VXI 75000 Series User And Service Manual

C-size vxi mainframes
Table of Contents

Advertisement

STATus:QUEStionable:BLOWer:ENABle <mask>
STATus:QUEStionable:BLOWer:ENABle?
Parameters
Returned Data
Comments
Error Conditions
Reset Condition
Related
Commands
96 Programming the Enhanced Monitor
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
The
STATus:QUEStionable:BLOWer:ENABle
register for the BLOWer status group.
The
STATus:QUEStionable:BLOWer:ENABle
the value of the enable register for the BLOWer status group.
The enable register specifies which bits in the event register can generate a summary
bit. The instrument logically ANDs corresponding bits in the event and enable
registers, and ORs all the resulting bits to obtain a summary bit. Summary bits are,
in turn, recorded in another register. The blower summary bit is recorded in the
Questionable Condition Register. Enable registers are read-write. Enable registers
are not affected by *CLS (Clear status). Querying enable registers does not affect
them.
Name
Type
Range
<mask>
int16
0 - 32767
Type
Range
int16
0 - 32767
mask value.
Refer to
STATus:QUEStionable:BLOWer:CONDition?
bit in the BLOWer status group.
If *PSC was set to 0 prior to power-down, then at power-on, the enable
registers are loaded from non-volatile memory. Therefore, any values that you
have stored (
SYSTem:NVSave
However, if *PSC was set to 1, then at power-on the factory defaults are
returned.
The following table lists the most common error conditions and causes. Error
numbers and corresponding messages can be found using
Number
Message
-222
"Data out of range"
*RST resets register the last value saved by the SYST:NVS command. Use
to clear the enable registers of the OPERation status group and the
STATus:PRESet
QUEStionable status group.
STATus:QUEStionable:BLOWer:CONDition?,
STATus:QUEStionable:BLOWer:EVENt?, STATus:PRESet, SYSTem:NVSave,
*PSC
command sets the value of the enable
query returns an integer representing
Default
7
Bit mask indicating which enable bits are
(see 2nd
set (1) or cleared (0) for the BLOWer
comment)
status group.
Description
command) are returned to the registers.
Probable Cause
The <mask> value was invalid.
Description
for a description of each
query.
SYSTem:ERRor?
Chapter 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vxi e8402aVxi e8404a

Table of Contents