HISTory:RESet[:ALL]

HISTory:RESet:BLOWer [<blower>]
HISTory:RESet:CURRent [<supply>]
HISTory:RESet:POWer [<supply>]

HISTory:RESet:QUEue

HISTory:RESet:TEMPerature [<slot>]
HISTory:RESet:VOLTage [<supply>]
Parameters
Command
Parameter(s) Range Default
[:ALL]
:BLOW <blower> BLOWer1,
BLOWer2,
BLOWer3
:CURR <supply>
P5, P12, N12, P24,
N24, N5PT2, N2,
P5STby
:POW <supply>
P5, P12, N12, P24,
N24, N5PT2, N2, TOTal
:QUE
:TEMP <slot>
OUT0...OUT12,
DELTa0...DELTa12,
AMBient
PSUPply
:VOLT <supply>
P5, P12, N12, P24,
N24, N5PT2, N2
74 Programming the Enhanced Monitor
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
The
commands erase all data being held by the HISTory subsystem:
HISTory:RESet
histograms, minimum/maximum values, and the history queue. For example,
erases all historical data;
HIST:RES:ALL
stored for the specified <blower>,
data for the specified <supply>, etc. The
stripchart data. The following table describes the commands and their parameters.
These commands are not allowed while the mainframe's power is off.
Erases all historical data. The history queue retains two entries
(ALL HISTORY RESET, and QUEUE RESET) marking the time
between manufacture and the HISTory:RESet. These commands
are not allowed while the mainframe's power is off.
none
Selects the fan whose historical data is to be erased. BLOWer1 is
the main cooling fan, BLOWer2 is the Power Supply cooling fan,
BLOWer3 is a second Power Supply cooling fan on the Agilent
E8404A mainframes.
none
Erases the amperage historical data for the selected <supply>.
Selects the power supply whose historical data is to be zeroed.
P5 is positive 5 Vdc supply, N12 is negative 12 Vdc supply, etc.
none
Erases the wattage historical data for the <supply>. Selects the
power supply whose historical data is to be zeroed. P5 is
positive 5 Vdc supply, N12 is negative 12 Vdc supply, etc.
Erases all the events stored in the history queue. One event is
put in the history queue on this command: an event logging the
time since manufacture of the mainframe until the
HIST:RES:QUE command. This is a completely destructive
command. There is no retrieving the history queue. It is primarily
needed if the history queue has filled up.
none
Absolute Slot Temperature Histogram
Delta Slot Temperature Histogram
Ambient Temperature Histogram
Power Supply Temperature Histogram
none
Erases the voltage historical data for the selected <supply>.
P5 is positive 5 Vdc supply, N12 is negative 12 Vdc supply, etc.
erases the historical data
HIST:RES:BLOW
erases the amperage historical
HIST:RES:CURR
command does not erase
HISTory:RESet