Output Power Specifications

Total Available and
Usable Power
Peak and Dynamic
Current
222 Agilent E8402, E8404A Product
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Product
Temperature
E8402A
0-55° C
E8404A
0-55° C
a.Sum of voltages times currents. Not always usable due to thermal protection
shutdown.
b.Total output before thermal protection shutdown or safety limitation.
E8402A
Peak Current,
,
a
b
Voltage
I
MP
+5V
50A
+12V
6A
-12V
4A
+24V
4A
-24V
4A
-5.2V
20A
-2V
10A
a.
Specifications apply at the backplane, 0-55° C.
b.
IMP = Rated mainframe peak DC output current as defined by the VXIbus Specification.
c.
IMD = Rated mainframe peak-to-peak dynamic current as defined in the VXIbus Specification by
a current vs. frequency curve.
a
Available Power
Usable Power
90-264VAC
110-264VAC
686 W
500 W
1,902 W
1,000 W
Dynamic Current,
Peak Current,
a
c
I
,
I
MD
MP
5A
90A
1A
15A
1A
15A
2A
15A
2A
15A
2A
60A
1A
30A
Usable Power b
b
90-110VAC
500 W
950W
E8404A
Dynamic Current,
a
b
a
c
,
,
I
MD
9A
2.5A
2.5A
5A
5A
8A
5A