Status:questionable:temperature:level? <Slot>[,Min|Max] - Agilent Technologies VXI 75000 Series User And Service Manual

C-size vxi mainframes
Table of Contents

Advertisement

STATus:QUEStionable:TEMPerature:LEVel? <slot>[,MIN|MAX]
Parameters
Returned Data
Comments
Reset Condition
Chapter 3
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
The
STATus:QUEStionable:TEMPerature:LEVel?
representing the present temperatures, in degrees Celsius, in the mainframe.
Name
Type
Range
<slot>
enum. OUT0...OUT12,
DELTa0...DELTa12
AMBient
optional
enum.
MIN, MAX
parameter
Type
Range
int16, int16, int16
-100 to +100
When querying AMBient, MIN, or MAX temperature, the same temperature is
returned in all three values. The measurements returned for any <slot> are the
last measurements taken. In normal operation, this is a measurement taken
during the last 2 seconds. If a *TST? or CAL? are being performed, the
measurements returned by this query are the last measurements taken before
the long operation started. If the mainframe power is off, the measurements
returned by this query are the last measurements taken before power went
down.
Refer to "Setting Enhanced Monitor Limits" on page 36 for information on
selecting and using temperature limits.
*RST does not affect the temperatures. It can affect the maximums and minimums
if a limit was set and not saved with the
query returns three integers
Default
Description
none
Last measured exhaust temperature
for slots 0 - slot 12
Last measured temperature change
above the ambient temperature for
slot0 - slot 12
Last measured entrance air
temperature
none
Adding MIN or MAX to the query
returns the present threshold being
used to determine temperature
warnings.
Default
Description
°
none
Temperature, in
three sensors: front, middle, rear
command.
SYSTem:NVSave
Programming the Enhanced Monitor
C, from each of the
113

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vxi e8402aVxi e8404a

Table of Contents