Trace[:Data]:Preamble? <Name - Agilent Technologies VXI 75000 Series User And Service Manual

C-size vxi mainframes
Table of Contents

Advertisement

TRACe[:DATA]:PREamble? <name>
Parameters
<name>
Returned Data
Chapter 3
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
returns the measurement envelope for the last requested
TRACe:PREamble?
<name> trace.
Name
Type
Range
enum.
OUTF0..OUTF12
OUTM0..OUTM12
OUTR0..OUTR12
AMBient
PSUPply
VP5
VP12
VN12
VP24
VN24
VN5PT2
VN2
P5STdby
P5EXt
IP5
IP12
IN12
IP24
IN24
IN5PT2
IN2
TPWR
BLOW1
BLOW2
BLOW3
Type
<format>
int8
<type>
int8
<points>
int16
<count>
int8
<xincrement>
int8
<xorigin>
int32
<xreference>
int8
<yincrement>
float32
<yorigin>
int8
<yreference>
int8
Default
none
slot 0 through 12 front temperatures
slot 0 through 12 middle temperatures
slot 0 through 12 rear temperatures
mainframe intake air temperature
Power Supply Temperature
5V supply voltage
12V supply voltage
-12V supply voltage
24V supply voltage
-24V supply voltage
-5.2V supply voltage
-2V supply voltage
5V Standby voltage
External % Voltage
5V supply amperage
12V supply amperage
-12V supply amperage
24V supply amperage
-24V supply amperage
-5.2V supply amperage
-2V supply amperage
total power on all seven supplies
Main Cooling Fan
Power Supply Cooling Fan
Power Supply Cooling Fan (Agilent E8404
only)
Range
Default
0,1
0
see FORMat:BORDer? A 0 is
normal, a 1 indicates swapped byte
order.
1
1
always raw data
0 to 360
360
identical to TRACe:POINts?
1
1
always 1.
-10
-10
each reading is 10 seconds apart.
0 -
none
seconds since power-on when last
2,147,483,648
reading was taken.
0
0
always 0.
-100 to 100
none
conversion factor for integer value to
float.
0
0
always 0.
0
0
always 0.
Programming the Enhanced Monitor
Description
Description
171

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vxi e8402aVxi e8404a

Table of Contents