SNTP
The printer clock can be synchronized with an NTP server clock using the Simple Network Time Pro-
tocol (SNTP). To change the SNTP settings, use the "sntp" command.
Limitation
SNTP supports NTP servers running xnptd V3 and V4.
Reference
msh> sntp
NTP Server Address Configuration
You can specify the NTP server's IP address.
msh> sntp server IP_address
Interval Configuration
You can specify the interval at which the printer synchronizes with the operator-specified NTP serv-
er.
msh> sntp interval polling_time
Note
The factory default setting is 3,600 seconds.
You can set the interval from 16 to 16,384 seconds.
If you set 0, the printer synchronizes with the NTP server only when you turn the printer on. After
that, the printer does not synchronize with the NTP server.
Operating Instructions
Administrator Reference
219