82 Installation and configuration
5
6
7
Installing superloop cables
The number of A0634496 Remote Superloop cables required to connect
the Remote IPE I/O panel 24-pin Centurions connectors to the 37-pin D
Shell SUPERLOOP connectors on the Fiber Remote Multi-IPE Interface
I/O panel depends on the number of superloops required to support the
Remote IPE site configuration.
To install these cables, use longer screws to install them into the I/O panel
cutouts and follow the steps in
(page
Procedure 22
Installing superloop cables
Step
1
2
3
Copyright © 2007-2009 Nortel Networks
.
Place the wall mount bracket in the upper rear corner of the
Fiber Remote Multi-IPE Interface unit and fasten it to the Ground
lug with the attached nut and lock washer.
Position the Fiber Remote Multi-IPE Interface unit's holes over
the two screws on the wall, insert the screws into the holes,
and push the Fiber Remote Multi-IPE Interface unit to the left to
engage the screws into the narrow of the slots.
Fasten the top of the wall mount bracket to the wall with the
provided screw.
Note:
Use the superloop connection plan that was completed based
on the traffic blocking criteria for Remote IPE segments and
"Superloop connection configurations" (page
82).
Action
Locate all the superloop connectors on the Remote IPE I/O
panel designated to support Remote IPE sites over fiber-optic
links.
Verify that the appropriate version of the Fiber Remote Multi-IPE
Interface unit (number of superloops and type of fiber supported)
have been configured and installed.
Refer to
Table 3 "Equipment required to link local system to
Remote IPE sites" (page
Plug the 24-pin Centronics A0634496 Remote Superloop cable
connector into the designated 24-pin I/O panel connector on the
Remote IPE module.
Refer to
Figure 17 "Remote site single Fiber Remote Multi-IPE
Interface unit cable connection diagram" (page 154)
connection diagram.
Nortel Communication Server 1000
Fiber Remote Multi-IPE Interface Fundamentals
NN43021-556 03.01
11 May 2009
--End--
14).
Procedure 22 "Installing superloop cables"
16).