Fiber remote multi-ipe interface fundamentals
Table of Contents

Advertisement

56 Installation and configuration
Figure 7
Installing the redundant fiber-optic link option
Mounting the Fiber Remote Multi-IPE Interface units
The Fiber Remote Multi-IPE Interface unit can be installed onto a wall or
into a rack-mounted shelf that accommodates up to six Fiber Remote
Multi-IPE Interface units. These units must be installed within 30 feet from
the local system and the Remote IPE, because the cables connecting the
Fiber Remote Multi-IPE Interface units to the local equipment are 30 feet
long. The power cable between the Fiber Remote Multi-IPE Interface unit
and its AC/DC Power Converter is only 25 feet long.
Two slotted holes are provided at the back of the enclosure to mount the
Fiber Remote Multi-IPE Interface unit on the wall such that the faceplate
is located on the left-hand-side and the I/O panel at the right-hand-side of
the unit.
For multiple Fiber Remote Multi-IPE Interface units, a rack-mounted shelf
is provided to house up to six units. This is normally used at the local site,
where the possibility of having multiple units is much greater.
Copyright © 2007-2009 Nortel Networks
.
Nortel Communication Server 1000
Fiber Remote Multi-IPE Interface Fundamentals
NN43021-556 03.01
11 May 2009
--End--