Table 2
Superloop connection configurations (cont'd.)
Remote IPE Segments
per Superloop
(Max 4 segments per
one IPE module)
Two segments per
superloop
and six segments per
another superloop
Note: NT8D01BC Controller -4 replaces both NT8D01AC Controller-4 and NT8D01DC Controller-2
for new installations.
From
following can be concluded for each configuration:
Copyright © 2007-2009 Nortel Networks
.
Connecting from
the local system
Superloop
Network Card
NT8D04 #1
NT8D04 #2
NT8D04 #2
Table 2 "Superloop connection configurations" (page
One segment per superloop. Requires transmission of four superloop
links over the Fiber Remote Multi-IPE Interface and the fiber-optic link
to a single Remote IPE module. Note that each Remote IPE module is
divided into four segments. Call connections are not blocked.
Two segments per superloop. Requires transmission of two
superloop links over the Fiber Remote Multi-IPE Interface and
the fiber-optic link to each Remote IPE module. Minimal to no call
blocking.
Four segments per superloop. Requires transmission of one
superloop link over the Fiber Remote Multi-IPE Interface and the
fiber-optic link to each Remote IPE module. Call blocking in high traffic
conditions.
Eight segments per superloop. Requires transmission of two
superloop links over the Fiber Remote Multi-IPE Interface and the
fiber-optic link to two Remote IPE modules. Call blocking in high traffic
conditions.
One segment for one superloop and three segments for the
second superloop. Requires transmission of two superloops over the
Fiber Remote Multi-IPE Interface and the fiber-optic link to a single
Remote IPE module. No call blocking for one segment, blocking for
the rest.
Two segments for one superloop and six segments for another
two superloops. Requires transmission of three superloops over the
Fiber Remote Multi-IPE Interface and the fiber-optic link to two Remote
IPE modules. Minimal blocking for the first four segments in one IPE
Nortel Communication Server 1000
Fiber Remote Multi-IPE Interface Fundamentals
NN43021-556 03.01
11 May 2009
Connecting to Remote IPE
Faceplate
Controller
Connector
Card
J2
NT8D01BC #1
J2
NT8D01BC #1
J1
NT8D01BC #2
System description 15
Backplane
Connector
SL0
SL1
SL0
14), the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Communication server 1000e cp piiCommunication server 1000e cp pivCommunication server 1000e cp pmCommunication server 1000m single group cp piiCommunication server 1000m single group cp pivCommunication server 1000m multi group cp pii ... Show all

Table of Contents