Nortel Communication Server 1000 Series Manual page 109

Fiber remote multi-ipe interface fundamentals
Table of Contents

Advertisement

5
6
7
8
Forced switch-over
This is a bidirectional switch-over. To conduct this test, follow the steps in
Procedure 33 "Performing a forced switch-over" (page
Procedure 33
Performing a forced switch-over
Step
1
2
3
4
5
6
Fault recovery test
This test verifies the recovery of the fiber-optic link and the Fiber Remote
Multi-IPE Interface units after the loss of power at one end. To perform
this test, follow the steps in
(page
Copyright © 2007-2009 Nortel Networks
.
Reconnect the link ST optical connector into the XMIT A
connector on the Fiber Remote Multi-IPE Interface faceplate.
Switch the link back to the primary by unplugging the secondary
link connector from the Fiber Remote Multi-IPE Interface
faceplate XMIT B connector.
Verify that the call is still established over the primary link.
Reconnect the link ST optical connector into the XMIT B
connector on the Fiber Remote Multi-IPE Interface faceplate.
Action
Check the status of the fiber-optic link by executing the D S
command from the MMI terminal.
Make sure that both the primary and the redundant links are
functional without an alarm condition on the Fiber Remote
Multi-IPE Interface faceplate.
Establish a call from the Remote IPE to the local site.
Refer to
"Voice calls" (page 105)
Assuming that the traffic is carried by the primary link, switch the
link to the secondary by executing the Set Link command S L B
to select the redundant link B using the MMI terminal.
Verify that the call is still established over the secondary link.
Execute the Set Link command S L A to select the primary link A
using the MMI terminal.
Verify that the call is still established over the primary link.
110).
Nortel Communication Server 1000
Fiber Remote Multi-IPE Interface Fundamentals
NN43021-556 03.01
11 May 2009
Performing acceptance testing 109
--End--
to establish the call.
--End--
Procedure 34 "Perform a fault recovery test"
109).

Advertisement

Table of Contents
loading

This manual is also suitable for:

Communication server 1000e cp piiCommunication server 1000e cp pivCommunication server 1000e cp pmCommunication server 1000m single group cp piiCommunication server 1000m single group cp pivCommunication server 1000m multi group cp pii ... Show all

Table of Contents