Nortel Communication Server 1000 Series Manual page 25

Fiber remote multi-ipe interface fundamentals
Table of Contents

Advertisement

Table 2 "Superloop connection configurations" (page 14)
combinations of superloop connections to the Fiber Remote Multi-IPE
Interface. The flexibility of superloop use allows for system optimization,
which depends on the specific system configuration and traffic
requirements.
Maintenance functions
The Fiber Remote Multi-IPE Interface provides a DB-9 female (MAINT)
connector at the rear of the unit on the I/O panel. This connector is used
as the MMI terminal port at both the local and the remote sites.
This MMI terminal is used to perform the following functions:
The SDI connector, also located on the Fiber Remote Multi-IPE Interface
I/O panel, is used to connect the Fiber Remote Multi-IPE Interface to an
SDI card in the local system. An MMI terminal at the local site or at a
Remote IPE site can access the system through this SDI port at the local
site and perform configuration, maintenance, and test functions of the
system.
A modem port (MODEM) is also provided on the I/O panel. This DB-9
female connector connects a modem to the Fiber Remote Multi-IPE
Interface. The modem is used to connect an MMI terminal, which may
be located at a maintenance center. This maintenance center may be
located in a different city, but by using a modem and public or private
telephone facilities, it is able to access the Fiber Remote Multi-IPE
Interface equipment at the local and the remote sites. It can also access
the local SDI port for local system maintenance. This access is allowed
only to the system TTY and the MMI terminals directly connected to the
Fiber Remote Multi-IPE Interface MAINT port.
A Fiber Remote Multi-IPE Interface in a multiple unit configuration can
be accessed by logging in on an MMI terminal. An MMI terminal can
then access the local system for system maintenance or access a Fiber
Remote Multi-IPE Interface at the local or remote sites for maintenance
Copyright © 2007-2009 Nortel Networks
.
configuration of the fiber-optic link performance criteria, such as bit
error rate threshold
on-line and off-line diagnostic testing of the fiber-optic link and
superloops
retrieval of performance statistics, such as alarm log, error log, and
current performance statistics
clearing error log files and alarms
setting time and date
setting the name of the site and of the superloop links
Nortel Communication Server 1000
Fiber Remote Multi-IPE Interface Fundamentals
NN43021-556 03.01
11 May 2009
System description 25
lists various

Advertisement

Table of Contents
loading

This manual is also suitable for:

Communication server 1000e cp piiCommunication server 1000e cp pivCommunication server 1000e cp pmCommunication server 1000m single group cp piiCommunication server 1000m single group cp pivCommunication server 1000m multi group cp pii ... Show all

Table of Contents