134 Remote IPE maintenance
2
3
4
Copyright © 2007-2009 Nortel Networks
.
FII:: >L
Enter Password > FIBER
Type D A [P] (DISPLAY ALARM) to display near-end superloop
and fiber-optic link alarm history. Type D A D (DISPLAY ALARM
DISTANT) to display far-end superloop and link alarm history.
The [P] or pause, allows a display of a full screen of events at
the time.
The response is displayed on the screen and shows the time
and date,
of each alarm or error event.
Example:
FII::>D A
Fiber Remote IPE S/N 2502-R3 Software Version 3.11
5/15/96
10:45
Local Site
In Alarm State: NO (superloops are not in the alarm
state)
01/22/96 09:26 No Activity Superloop 1
01/22/96 09:26 Activity On Superloop 1
01/22/96 09:25 No Activity Superloop 1
01/22/96 09:25 Activity On Superloop 1
01/22/96 09:24 No Activity Superloop 4
01/22/96 09:20 No Activity Superloop 3
01/22/96 09:17 Activity On Superloop 4
01/22/96 09:17 Activity On Superloop 3
01/22/96 09:17 Activity On Superloop 2
01/22/96 09:17 Fiber Link Up
01/22/96 09:16 Fiber A Threshold Exceeded
01/22/96 09:16 Fiber Link Down
01/22/96 09:15 Performed a Power Up Reset
01/22/96 09:15 Initialized Memory
01/22/96 09:10 Log Cleared
Clear the near-end (local) alarm log by executing the C AL
(CLEAR ALARM) and the far-end (remote) by executing the C AL
D (CLEAR ALARM DISTANT) command.
Type D E [P] (DISPLAY ERROR) to display near-end superloop
and fiber-optic link error history. Type D E D (DISPLAY ERROR
DISTANT) to display far-end superloop and fiber-optic link error
history. The [P] or pause, allows you to display a full screen of
events at the time.
Nortel Communication Server 1000
Fiber Remote Multi-IPE Interface Fundamentals
NN43021-556 03.01
11 May 2009
Login command
Type in the password.