Nortel Communication Server 1000 Series Manual page 147

Fiber remote multi-ipe interface fundamentals
Table of Contents

Advertisement

Procedure 50
Removing and replacing the card in the Fiber Remote Multi-IPE Interface unit
Step
1
2
3
4
5
6
7
8
9
Reinstalling covers
When it is determined that the Remote IPE is operating correctly, follow
the steps in
Procedure 51
Reinstalling covers
Step
1
2
Copyright © 2007-2009 Nortel Networks
.
Action
Log in on the TTY or the MMI maintenance terminal.
Disable the Superloop Network card by loading the Network and
Intelligent Peripheral Equipment Diagnostic Program LD 32, and
executing DIS sl, where sl is the actual superloop number of
the Superloop Network card.
Disconnect the fiber-optic ST connectors from the Fiber Remote
Multi-IPE Interface unit faceplate XMIT A and RCV A optical
connectors.
If the link is redundant, also disconnect the link from the
faceplate connectors XMIT B and RCV B.
Remove the card from the Fiber Remote Multi-IPE Interface unit
by pulling the extractors away from the enclosure.
Reinstall a replacement Fiber Remote Multi-IPE Interface
card into the enclosure in reverse order by setting the S1 and
S2 dip-switches, installing the card into the enclosure, and
connecting the fiber-optic link to the faceplate optical connectors.
Check the power LED on the Fiber Remote Multi-IPE Interface
unit.
It should be lit permanently if the unit passed self-test upon
power up.
Enable all superloops by executing the ENLL sl command.
Press the Reset button to turn off the alarm LEDs.
Tag the defective Fiber Remote Multi-IPE Interface card(s) with a
description of the problem and prepare them for shipment to the
equipment supplier's repair depot.
Procedure 51 "Reinstalling covers" (page
Action
Reinstall the covers on the local module.
Reinstall the cover on the Remote IPE module.
Nortel Communication Server 1000
Fiber Remote Multi-IPE Interface Fundamentals
NN43021-556 03.01
11 May 2009
Replacing Remote IPE equipment 147
--End--