Chapter 9
Replacing media drives
In this chapter
"Replacing a faulty hard drive" (page 99)
"About the media drive bay" (page 103)
"Removing the media drive carrier from the chassis" (page 103)
"Replacing a tape, CD-ROM or floppy drive" (page 106)
"Installing a tape drive" (page 108)
Replacing a faulty hard drive
The hard drives are hot-swappable. This means that you can replace a
faulty hard drive without powering down the server.
Replacement hard drives must be the same size or larger than the hard drives
being replaced
When to hot-swap hard drives
With a RAID controller, hot-swap device drivers, and operating system
support, faulty SCA SCSI hard drives can be hot-swapped on the 1002rp
server.
Use the RAID management software to check if any drives are in a failed
state.
Copyright © 2007, Nortel Networks
.
Note: Identify which hard drive to remove using the Windows Event
Viewer (see
"Viewing event logs" (page
codes such as 40211(disk access error) or 40218 (error reading or
writing multimedia volume) may be an indication of a failing disk drive.
Nortel CallPilot
1002rp Server Maintenance and Diagnostics
NN44200-701 01.02 Standard
5.0 4 April 2007
ATTENTION
23)). The appearance of event
99
Nortel Networks Confidential