122 Chapter 10 RAID operations
To synchronize the RAID after an unsuccessful operation
Step
If the operation has failed, the system needs to be returned to the original
configuration.
1
2
3
4
5
6
7
Copyright © 2007, Nortel Networks
.
Action
Reboot the CallPilot server.
Press Ctrl+M while the server is booting.
Result: The RAID configuration utility opens.
Break the mirroring of the logical drives.
a. Select Objects → Physical Drive.
Note: All server drives on channel 1 must be online.
b. Select CH1 ID0 (A01-01) and press Enter.
c. Select Fail Drive and press Enter.
d. Select Yes to confirm the fail action and press Enter.
e. Repeat these steps for each remaining drive on channel 2: CH1
ID1 (A02-01) and CH1 ID2 (A03-01).
Bring the drives on channel 2 online (the drives on which the
previous CallPilot release is installed).
a. Select Objects → Physical Drive.
b. Select CH2 ID0 (A01-02) and press Enter.
c. Select Make Online and press Enter.
d. Select Yes to confirm that the driver must be brought online
and press Enter.
e. Repeat these steps for each remaining drive on channel 2: CH2
ID1 (A02-02) and CH2 ID2 (A03-02).
Press Esc to return to the Objects menu.
Press Esc to return to the Management menu.
Press Esc to exit the RAID configuration utility.
Result: A confirmation box appears.
Nortel CallPilot
1002rp Server Maintenance and Diagnostics
NN44200-701 01.02 Standard
5.0 4 April 2007
—End—