128 Chapter 11 Configuring MPB96 boards
Installing valid configurations
You must use one of the valid configurations and respect the slot map or the
system behavior will be erratic.
T1 switch connectivity
To configure one MPB96 and two T1 PCI cards
Step
1
2
3
4
5
6
To configure three MPB96 and four T1 PCI cards
Step
1
2
Copyright © 2007, Nortel Networks
.
Action
Plug the MPB96 card in PCI slot 3.
On the first Intel D/480JCT-2T1 PCI card:
a. Set the card SW100 ID rotary dial switch to 0.
b. Ensure that there are no termination jumpers installed on P700.
Plug the first Intel D/480JCT-2T1 PCI card 1 in PCI slot 4.
On the second Intel D/480JCT-2T1 PCI card:
a. Set the card SW100 ID rotary dial switch to 1.
b. Install a termination jumper on P700 3&4 termination jumpers
ON (to enable CT Bus termination).
Note: Only one Intel D/480JCT-2T1 PCI card in the system (the
last on the CT Bus cable) should have the termination jumper
set to ON.
Plug the Intel D/480JCT-2T1 PCI card 1 in PCI slot 5.
Connect the 3 drop CT-Bus cable so all three connectors are
securely connected to all cards.
Note: If a 7 drop cable is used in this configuration, ensure
that the end connectors are connected to the end cards and no
connector is left dangling at any end of the cable.
Action
Plug the MPB96 card in PCI slot 3.
On the first Intel D/480JCT-2T1 PCI card:
Nortel CallPilot
1002rp Server Maintenance and Diagnostics
NN44200-701 01.02 Standard
5.0 4 April 2007
ATTENTION
—End—