Nortel CallPilot User Manual page 120

Nortel callpilot: user guide
Hide thumbs Also See for CallPilot:
Table of Contents

Advertisement

120 Chapter 10 RAID operations
To perform a consistency check
Step
1
2
3
4
5
6
7
To split the RAID
Step
To split the RAIDBecause the 1002rp has three physical drives, the RAID splitting
must be done at the Ctrl+M utility level. Do not perform this procedure using the
Windows MegaRAID console. There is a risk of database corruption.
1
2
3
4
Copyright © 2007, Nortel Networks
.
Action
Restart the CallPilot system and press Ctrl+M when prompted, to
enter the RAID setup utility during bootup.
From the Management Console, select Check Consistency.
Result: The Logical Drives Configured dialog box displays.
Use the arrow key to highlight the first drive to be checked.
Press the space key to select the drive.
Press F10 to check consistency.
Result: The "Do you wish to continue?" dialog box appears.
Click Ok.
Result: The consistency check begins and a status dialog box
appears.
Repeat steps 3 to 6 for each drive until all three drives have been
checked for consistency.
Action
Restart the CallPilot system and press Ctrl+M when prompted, to
enter the RAID setup utility during bootup.
From the Management menu select Objects > Physical Drive.
Result: A list of all drives organized per channel appears.
Select the A01- 2 drive using the cursor and press Enter.
Select Fail Drive.
Result: A warning message box appears. Ignore it and select Yes.
The drive status changes to FAILED. The alarm should start beeping.
Nortel CallPilot
1002rp Server Maintenance and Diagnostics
NN44200-701 01.02 Standard
5.0 4 April 2007
—End—