Replacing the SCA SCSI drive cage and fused power cable 85
Open the Physical Devices window and check the drive pair settings.
The table below shows the correct settings.
Drive pair settings
LED
ID
Channel-1
No
0
0
ONLIN A01-01
1
1
ONLIN A02-01
2
2
ONLIN A03-01
Note: If your settings do not match those in the table, stop
and contact your next level of support for assistance before
continuing.
Check that all drives are marked in green and Online.
Note: If they are not all online, stop and contact your next level
of support for assistance before continuing.
Check the RAID drive consistency:
a. Select Check Consistency.
Result: The Logical Drives Configured dialog box appears.
b. Use the arrow key to highlight the first drive to be checked.
c. Press the space key to select the drive.
d. Press F10 to check consistency.
Result: The Do you wish to continue? dialog box appears.
e. Click Ok.
Result: The consistency check begins and a status dialog box
appears.
f.
Repeat steps c to e for each drive until all three drives have
been checked for consistency. This may take up to 2 hours to
complete. If any data consistency errors are detected, they are
corrected automatically.
Perform a full-system backup of the CallPilot server (either to tape
or file server).
Review the backup logs to verify success.
Perform a controlled shutdown of the CallPilot software:
a. Click Ctrl+Alt+Delete and select Shutdown from the Windows
Security window.
Nortel CallPilot
1002rp Server Maintenance and Diagnostics
NN44200-701 01.02 Standard
5.0 4 April 2007