Nortel CallPilot User Manual page 137

Nortel callpilot: user guide
Hide thumbs Also See for CallPilot:
Table of Contents

Advertisement

Manually setting T1 card manual termination jumpers
Manually set T1 card manual termination jumpers only on the last card at
the end of the CTbus.
Risk of equipment damage
Do not install this jumper on any of the other T1 cards.
Apply a jumper between pins 3 and 4 of the P700 header on the
Intel/Dialogic D/480JCT-2T1 card. The diagram below shows a detail of
the T1 card.
D/480JCT-2T1 card
To test the D/480JCT-2T1 card
Test the D/480JCT-2T1 card using the Universal Dialogic Diagnostic (UDD)
utility.
Step
1
Copyright © 2007, Nortel Networks
.
Note: Before running this utility, you must stop essential services.
All call processing ceases and you must restart the system after the
diagnostics are complete.
Action
Stop the CallPilot HAL Monitor service. Refer to
component" (page 57)
Nortel CallPilot
1002rp Server Maintenance and Diagnostics
NN44200-701 01.02 Standard
5.0 4 April 2007
TD/480JCT-2T1 card function 137
—End—
ATTENTION
for instructions.
"To start or stop a
Nortel Networks Confidential