148 Chapter 14 Maintaining the Pentium III SBC card
To add SDRAM DIMMs to the SBC card
Step
1
2
3
4
5
6
7
8
Copyright © 2007, Nortel Networks
.
Action
CAUTION
Risk of electrical damage
Wear an antistatic ESD wrist strap when handling cards or boards,
or when working inside the server.
Remove the SBC card from the server and place it down on a flat
surface.
Note: To remove old DIMMs, perform steps
DIMMs, go to step 5.
Push the DIMM release tab outwards at both sides of the DIMM
to be removed.
Hold the DIMM by its edges, being careful not to touch its
components. Remove the DIMM by lifting it away from its slot. Store
it in an antistatic package.
Remove other DIMMs as necessary.
Orient the DIMM so that the two notches in the bottom edge of the
DIMM align with the keyed slot.
Insert the bottom edge of the DIMM into the slot, and press down
firmly on the DIMM until it seats correctly.
When the DIMM seats correctly, release the tabs lock back to an
upright position. If the DIMM does not seat correctly, remove it and
reinstall. Do not force the locking tabs to close.
Note: The optional DIMMs can be installed when the SBC is
in the server. If you do this, you must ensure that the server is
powered off, and you must support the back of the SBC when
you press the DIMM into the slot.
Repeat steps 5 and 6 to install each additional DIMM.
Replace the SBC card in the server.
Nortel CallPilot
1002rp Server Maintenance and Diagnostics
NN44200-701 01.02 Standard
5.0 4 April 2007
—End—