MTU
Setup Alarm Threshold
Clear Alarm Threshold
Code Sent
Cable Length
Payload Type
T3 over Mcoc3 Ds3 summary
Slot/Conn/Channel
Administrative State
Operational State
Alarms
Linecoding
Framing
Actual Framing
Pri/Sec Clock
Actual Clock
308689-B Rev 00
Displays largest frame size that can be received by the
MCT3 channel. Anything larger than the MTU will be
discarded.
Minimum amount of time required before entering (or
exiting) an alarm state due to changes on the DS3.
Displays type of code last sent across the MCT3 circuit
by the device. Possible values are: sendnocode (sending
looped or normal data), sendlinecode (sending a request
for a line loopback), sendpayloadcode (sending a
request for a payload loopback), and sendds1loopcode
(sending a request for a DS1 loopback).
Parameter set according to cable length. Possible values
are short (less than 225 feet), or long (greater than 225
feet).
Type of payload to be sent through the DS3 connector.
Possible values are: not yet configured (selected) (1),
channelized DS1 (2), fractional DS3 (3) and clear channel
DS3 (4).
Identifier for the slot, OC3 connector, T3 channel.
Displays administrative state.
Displays operational state.
Displays alarm state.
Displays the variety of zero code suppression used on the
link, which in turn affects a number of its characteristics.
The only value allowed here is B3ZS.
Framing mode. Possible values here are autodetect,
C-bit, or M23.
Actual framing currently used on the line. Possible values
are C-bit, or M23. Note that this can be different than the
configured line type when the autodetect value is used.
Displays configured primary/secondary source of the Tx
clock for the MCT3 channel interface.
Displays clock source currently in use by the MCT3
channel interface.