Nortel Versalar 15000 Installing And Maintaining

Switch router
Hide thumbs Also See for Versalar 15000:
Table of Contents

Advertisement

Quick Links

Installing and Maintaining the
Versalar Switch Router 15000
Part No. 308684-B Rev 00
March 2000
4401 Great America Parkway
Santa Clara, CA 95054

Advertisement

Table of Contents
loading

Summary of Contents for Nortel Versalar 15000

  • Page 1 Part No. 308684-B Rev 00 March 2000 4401 Great America Parkway Santa Clara, CA 95054 Installing and Maintaining the Versalar Switch Router 15000...
  • Page 2 Nortel Networks NA Inc. does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein.
  • Page 3 EC Declaration of Conformity This product conforms (or these products conform) to the provisions of Council Directive 89/336/EEC and 73/23/EEC. The Declaration of Conformity is available on the Nortel Networks World Wide Web site at http://libra2.corpwest.baynetworks.com/cgi-bin/ndCGI.exe/DocView/. Japan/Nippon Requirements Only Voluntary Control Council for Interference (VCCI) Statement...
  • Page 4 Software is provided will be free from defects in materials and workmanship under normal use for a period of 90 days from the date Software is first shipped to Licensee. Nortel Networks will replace defective media at no charge if it is returned to Nortel Networks during the warranty period along with proof of the date of shipment.
  • Page 5 Licensee will immediately destroy or return to Nortel Networks the Software, user manuals, and all copies. Nortel Networks is not liable to Licensee for damages in any form solely by reason of the termination of this license. 8. Export and Re-export. Licensee agrees not to export, directly or indirectly, the Software or related technical data or information without first obtaining any required export licenses or other governmental approvals.
  • Page 7: Table Of Contents

    Text Conventions ......................xviii Acronyms ........................xviii Hard-Copy Technical Manuals ..................xx How to Get Help ......................xx Chapter 1 Versalar 15000 Hardware Description Versalar 15000 Components ..................1-2 Processor Cards ......................1-4 Card Configuration Requirements ................1-4 Examples of Card Configuration ................1-6 Access Processor Cards ..................1-6...
  • Page 8 Verifying Shipment Contents ..................2-2 Supplying Equipment ....................2-5 Management Console ..................2-5 Cables ........................2-5 Hardware for Mounting the Versalar 15000 in an Equipment Rack ....2-6 Verifying Site Requirements ..................2-7 Space Requirements ..................2-7 AC Input Electrical Requirements ..............2-7 DC Input Electrical Requirements ..............2-8 Environmental Requirements ................2-9...
  • Page 9 Verifying a Successful Installation ..................5-2 Turning the Versalar 15000 On and Off ................5-3 Turning the Versalar 15000 with a DC Power Source On and Off ......5-3 Turning the Versalar 15000 with the AC Power Unit On and Off ......5-4 Resetting the Versalar 15000 ..................5-5...
  • Page 10 Hardware Communications Options ................A-2 Ethernet 10/100BASE-T Interface ................A-3 Local Console Interface ..................A-4 Service Modem Interface ..................A-5 OC-12c/STM-4c ATM Interface Card Specifications ............A-6 DS3 Interface Card Specifications ................. A-7 Versalar 15000 Card Glossary Index 308684-B Rev 00...
  • Page 11 Accessories in the Versalar 15000 Shipping Container ......2-4 Figure 2-2. SC Duplex to SC Duplex Cable ...............2-6 Figure 2-3. Three Versalar 15000 DC Platforms and Two AC Platforms in a Four-Post Rack ..................2-12 Figure 2-4. Attaching Angle Brackets in a 19-Inch Rack ..........2-14 Figure 2-5.
  • Page 12 Figure 3-12. Mounting the Separate AC Power Unit ..........3-20 Figure 3-13. Removing or Installing an AC Power Module .........3-21 Figure 3-14. Two Versalar 15000 Platforms with the AC Power Unit in a Four-Post Rack ..................3-24 Figure 3-15. AC Management Cable Location ............3-26 Figure 4-1.
  • Page 13 Figure 4-22. Dual Modem Access with a Single Telco Line ........4-35 Figure 5-1. Versalar 15000 Power Switch ..............5-3 Figure 5-2. Versalar 15000 Reset Switch ..............5-5 Figure 5-3. Alarm Mute Button ...................5-6 Figure 5-4. Removing the Memory Card Access Cover ..........5-7 Figure 5-5.
  • Page 15 OC-12c/STM-4c ATM Interface Card LEDs ...........1-37 Table 1-17. Quad OC-3 ATM Trunk Interface LEDs ..........1-39 Table 1-18. 1000M-LX Ethernet Trunk Interface LEDs ..........1-41 Table 2-1. Versalar 15000 Shipping Accessories .............2-3 Table 2-2. Network Cables ..................2-5 Table 2-3. Space Requirements ................2-7 Table 2-4.
  • Page 16 Table 4-3. PC Parameters ..................4-31 Table 4-4. Modem Settings ..................4-33 Table A-1. 10/100BASE-T Interface Pin Assignments ..........A-3 Table A-2. Local Console Port DB-9 Pin Assignments ..........A-4 Table A-3. Service Modem Port DB-9 Pin Assignments .......... A-5 Table A-4. Maximum Fiber Optic Power Budget and Transmission Distances ..
  • Page 17: Preface

    Before You Begin This guide is intended for qualified service personnel who are installing the Versalar 15000 for the first time or who need to install or replace any Versalar 15000 CRU. A qualified service person should have appropriate technical training and experience and be aware of the hazards involved in installing and replacing CRUs.
  • Page 18: Text Conventions

    Installing and Maintaining the Versalar Switch Router 15000 Text Conventions This guide uses the following text conventions: bold text Indicates command names and options and text that you need to enter. Example: Enter the command. diags italic text Indicates new terms, book titles, and variables in command syntax descriptions.
  • Page 19 Preface Electronic Industries Association electromagnetic interference ground Internet forwarding processor Internet Protocol light emitting diode loss of frame loss of signal multimode fiber normally closed NEMA National Electrical Manufacturers Association normally open OC-3 Optical Carrier-level 3 OC-12 Optical Carrier-level 12 packet over sonet remote defect indication reserved for future use...
  • Page 20: Hard-Copy Technical Manuals

    The “Technical Manuals” section lists available printed documentation sets. How to Get Help If you purchased a service contract for your Nortel Networks product from a distributor or authorized reseller, contact the technical support staff for that distributor or reseller for assistance.
  • Page 21: Versalar 15000 Hardware Description

    Chapter 1 Versalar 15000 Hardware Description This chapter introduces the Versalar Switch Router 15000 hardware and describes the light emitting diodes (LEDs) on each component. It includes the following topics: Topic Page Versalar 15000 Components Processor Cards Interface Cards 1-24...
  • Page 22: Versalar 15000 Components

    Installing and Maintaining the Versalar Switch Router 15000 Versalar 15000 Components The Versalar 15000 consists of a chassis that contains slots for these modules: • Processor cards (front of chassis) -- Five access processor (AP) cards -- Three Internet forwarding processor (IFP) cards...
  • Page 23: Processor Cards

    Versalar 15000 Hardware Description Figure 1-1 shows the location of the Versalar 15000 customer-replaceable units (CRUs). Access interface cards AP cards SSP interface IFP cards console card SSP cards interface Optional Trunk interface Ethernet TP cards cards card card Fan tray...
  • Page 24: Card Configuration Requirements

    • SSP cards provide layer 4 and above processing. Card Configuration Requirements Table 1-1 shows possibilities for installing the cards into the card slots in the Versalar 15000. Table 1-1. Installation Possibilities Performance AP Cards TP Cards Base Configuration Configuration Redundant Configuration...
  • Page 25 Versalar 15000 Hardware Description Table 1-1. Installation Possibilities (continued) Performance AP Cards TP Cards Base Configuration Configuration Redundant Configuration 5 AP cards in slots 1, 2, 3, 4, and 5 None 3 IFP cards in slots 6, 7, and 8...
  • Page 26: Examples Of Card Configuration

    AP1, AP2, AP3, AP4, AP5, TP11, TP12, IFP6, IFP7, IFP8, SSP9, SSP10 Access Processor Cards The Versalar 15000 supports four AP cards in chassis slots 1 to 5. Note: If you do not use all the slots from 1 to 5, use the lowest-numbered slots first.
  • Page 27: Ap Card Labels

    1 to 4. For more information about redundancy, see “Access Redundancy Module Interface Card” on page 1-26. The Versalar 15000 supports four types of AP cards: • The M13 channelized access processor (CAP) card is used for subrate T1 and T1 applications.
  • Page 28: Figure 1-2. M13/Ds3 Cap Card

    Installing and Maintaining the Versalar Switch Router 15000 Figure 1-2 shows an example of an M13/DS3 CAP card. All the AP cards are identical to this card. This illustration shows the card’s unique label identifier as well as the position of the LEDs. Stat Run M13/DS3 Slot...
  • Page 29: Ap Card Leds

    On (amber) Diagnostic testing failed. The CAP card is waiting for an automatic attempt to reinitiate diagnostic testing. If the Stat LED lights amber again, call the Nortel Networks Technical Solutions Center. The processor code is not loaded. On (green) The processor code loaded successfully.
  • Page 30 Installing and Maintaining the Versalar Switch Router 15000 Table 1-4 describes the DS3 status LEDs for all the AP cards. Table 1-4. DS3 Status LEDs State Meaning Ports 1 to 6 Port is not configured or the software is not initialized. Sync On (green) Port has achieved frame synchronization.
  • Page 31 Versalar 15000 Hardware Description Table 1-5 describes the OC-3 status LEDs for all types of AP cards. The OC-3 status LEDs are the same for all AP cards. Table 1-5. OC-3 Status LEDs State Meaning Sync (port n ) Frame synchronization is not detected on port.
  • Page 32: Internet Forwarding Processor Card

    Internet Forwarding Processor Card The Internet forward processor (IFP) card provides layer 3 IP switching for the Versalar 15000. The Versalar 15000 can support three IFP cards in chassis slots 6 to 8. Two or three IFP cards provide high-availability operation. If you have an access card in slot 1 or 2, use slot 6 for the IFP card.
  • Page 33: Figure 1-3. Ifp Card

    Versalar 15000 Hardware Description Figure 1-3 shows an IFP card. Stat Run AP1 SSP1 SSP2 Pwr Stat Run AP1 SSP1 SSP2 BAC0005A Figure 1-3. IFP Card 1-13 308684-B Rev 00...
  • Page 34 On (amber) Diagnostic testing failed. The IFP card is waiting for an automatic attempt to reinitiate diagnostic testing. If the Stat LED lights amber again, call the Nortel Networks Technical Solutions Center. Processor code is not loaded. On (green) Boot process is complete.
  • Page 35 Versalar 15000 Hardware Description Table 1-6. IFP Card LEDs (continued) State Meaning IFP card is not processing inbound packets for the CAP card present in processor card slot 5. On (green) IFP card is processing inbound packets for the CAP card present in processor card slot 5.
  • Page 36: System Services Processor Card

    Installing and Maintaining the Versalar Switch Router 15000 System Services Processor Card The systems services processor (SSP) card is the central processing resource on which the network layer protocols run. The SSP card is responsible for Versalar 15000 route determination, statistics, and central management. The Versalar 15000 can support two SSP cards in slots 9 and 10.
  • Page 37 Versalar 15000 Hardware Description Table 1-7 describes the SSP card LEDs. Table 1-7. SSP Card LEDs State Meaning Power is off. On (green) Power is on Stat LED is not functioning. On (green) SSP card is operating normally. Flashing (green) Power-up diagnostic testing is in progress.
  • Page 38: Trunk Processor Card

    Services operating system is executing, it uses these lights to count time. Trunk Processor Card The Versalar 15000 provides trunk line services for ATM and gigabit Ethernet. To accommodate trunk services, the Versalar 15000 supports up to two trunk processor cards in slots 11 and 12.
  • Page 39 Versalar 15000 Hardware Description Pwr Stat Run Pri Sec Stat Run Link Test RDI Port 1 Link Test RDI Port 1 Port 2 Port 2 Port 3 Port 4 Port 3 Port 4 BAC0006B Figure 1-5. ATM TP Card 1-19...
  • Page 40 Processor code is not loaded. On (green) Boot process is complete. Flashing (green) Booting. On (amber) A fault is detected. Call the Nortel Networks Technical Solutions Center. Trunk interface card is not installed. On (green) Trunk interface card is present. Not loaded.
  • Page 41: Packet Trunk Processor Card

    Versalar 15000 Hardware Description ATM OC-12c/STM TP Table 1-8. Card LEDs (continued) State Meaning Test (port n ) Port is operating in through mode. On (green) Port is operating in a loopback state. RDI (port n ) No remote fault is detected on the port.
  • Page 42 Installing and Maintaining the Versalar Switch Router 15000 Figure 1-6 shows the packet trunk processor card. Stat Run Phy POS Enet Stat Run RDI APS Phy POS Enet Link Test Pri Sec Enet 10/100 Link Test Enet 10/100 Port 1 Port 1 Port 2 Port 3...
  • Page 43 On (green) The boot process is complete. Flashing (green) The router is booting. On (amber) A fault is detected. Call the Nortel Networks Technical Solutions Center. The trunk interface card is not installed. On (green) The trunk interface card is present.
  • Page 44: Interface Cards

    Access Interface Cards The Versalar 15000 access interface cards occupy chassis slots 1 to 5 and support network interfaces for AP cards. The access interface cards are the Hex T3 (T3), ARM, Quad DS3, or Dual OC-3 interface cards, each of which is described in the sections that follow.
  • Page 45: Hex T3 (T3) Interface Card

    Versalar 15000 Hardware Description Hex T3 (T3) Interface Card The T3 interface card provides physical line interfaces for six T3 lines. The Versalar 15000 supports four or five T3 interface cards in slots 1 to 5. Figure 1-7 shows the T3 interface card.
  • Page 46: Access Redundancy Module Interface Card

    5 can then assume the processing duties of a failing AP card. With an ARM card installed in interface card slot 5 and a hybrid M13 and clear-channel DS3 CAP card installed in processor card slot 5, the Versalar 15000 supports failover of mixed clear-channel and channelized T3 configurations.
  • Page 47: Figure 1-8. Arm Interface Card

    Versalar 15000 Hardware Description Figure 1-8 shows the ARM interface card. Stat Stat BAC0064A Figure 1-8. ARM Interface Card 1-27 308684-B Rev 00...
  • Page 48: Dual Oc-3 Single-Mode Or Multimode Channelized Access Interface Card

    OC-3 lines with APS failover switching. (For information about SMF and MMF cards, refer to “Single-Mode and Multimode Interfaces” on page 1-36.) The Versalar 15000 supports four or five OC-3 interface cards in slots 1 to 5. 1-28 308684-B Rev 00...
  • Page 49: Figure 1-9. Dual Oc-3 (Smf Or Mmf) Channelized Access Interface Card

    Versalar 15000 Hardware Description Figure 1-9 shows the Dual OC-3 channelized access interface card. 2xOC3 M13 MMF Access Interface 2xOC3 M13 MMF Access Interface VRS0130A Figure 1-9. Dual OC-3 (SMF or MMF) Channelized Access Interface Card 1-29 308684-B Rev 00...
  • Page 50: Dual Oc-3 (Smf Or Mmf) Atm Access Interface Card

    The Dual OC-3 (SMF or MMF) ATM access interface card provides physical line interfaces for two ATM lines with APS failover switching. The Versalar 15000 supports four or five OC-3 interface cards in slots 1 to 5. (For information about SMF and MMF cards, refer to “Single-Mode and Multimode Interfaces”...
  • Page 51: System Services Processor Interface Cards

    Loss of signal detected. System Services Processor Interface Cards The Versalar 15000 system services processor (SSP) interface cards occupy chassis slots 9 and 10. They provide dedicated interfaces for out-of-band management, as well as system-wide status. The SSP interface cards are the SSP interface console card and the SSP interface Ethernet card, each of which is described in the sections that follow.
  • Page 52: Ssp Interface Console Card

    Installing and Maintaining the Versalar Switch Router 15000 SSP Interface Console Card The Versalar 15000 supports one SSP interface console card in slot 10 of the chassis. The SSP interface console card consists of a bezel with status LEDs, a...
  • Page 53 Versalar 15000 Hardware Description Table 1-14 describes the SSP interface console card LEDs. Table 1-14. SSP Interface Console Card LEDs State Meaning Power is off. On (green) Power is on. On (amber) SSP interface console card is defective. Call the Nortel Networks Technical Solutions Center.
  • Page 54: Ssp Interface Ethernet Card

    Installing and Maintaining the Versalar Switch Router 15000 SSP Interface Ethernet Card The Versalar 15000 supports one SSP interface Ethernet card in slot 9 of the chassis. The SSP interface Ethernet card supports the 10 Mb Ethernet interface. The SSP interface Ethernet card consists of an Ethernet 10/100 Mb connector, and...
  • Page 55 Versalar 15000 Hardware Description Table 1-15 describes the SSP interface Ethernet card LEDs. Table 1-15. SSP Interface Ethernet Card LEDs State Meaning Ethernet link is down. On (green) Link pulse received. Flashing (green) Port is transmitting or receiving data. Power is off.
  • Page 56: Trunk Atm Interface Cards

    Installing and Maintaining the Versalar Switch Router 15000 Trunk ATM Interface Cards The Versalar 15000 trunk interface cards occupy chassis slots 11 and 12 and support network interfaces for TP cards. This section contains information about the following cards: •...
  • Page 57: Figure 1-12. Oc-12C/Stm-4C Atm Interface Card

    Versalar 15000 Hardware Description OC12 Interface Multi-Mode OC-12 Interface Multi-Mode BAC0009A Figure 1-12. OC-12c/STM-4c ATM Interface Card Table 1-16 describes the OC-12c/STM-4c interface card LEDs. Table 1-16. OC-12c/STM-4c ATM Interface Card LEDs State Meaning Power is off. On (green) Power is on and operating normally.
  • Page 58: Quad Oc-3 Atm Trunk Interface Card

    Installing and Maintaining the Versalar Switch Router 15000 Quad OC-3 ATM Trunk Interface Card Figure 1-13 shows the Quad OC-3 ATM trunk interface card. The card consists of a printed circuit board, an EMI card shield, a bezel with status LEDs, and 2 captive screws to secure the card in place.
  • Page 59: Trunk Ethernet Interface Cards

    (port 1-4) On (amber) Loss of frame detected. Trunk Ethernet Interface Cards The Versalar 15000 trunk Ethernet interface cards occupy chassis slots 11 and 12 and support network interfaces for TP cards. This section contains information about the following cards: •...
  • Page 60: Figure 1-14. 1000M-Lx Ethernet Trunk Interface Card

    Installing and Maintaining the Versalar Switch Router 15000 Figure 1-14 shows the 1000M-LX Ethernet trunk interface card. 1000M-LX Enet Trunk Interface 1000M-LX Enet Trunk Interface Pwr SD Link/UD Pwr SD LinkU/D VRS0136A Figure 1-14. 1000M-LX Ethernet Trunk Interface Card 1-40 308684-B Rev 00...
  • Page 61: 1000M-Sx Ethernet Trunk Interface Card

    1000M-SX Ethernet Trunk Interface Card The SX Ethernet trunk interface card is a single-port 1000-base SX Ethernet module. The Versalar 15000 supports one or two SX Ethernet trunk interface cards. The 1000M-SX Ethernet trunk interface card looks exactly the same as the 1000M-LX Ethernet trunk interface card.
  • Page 63: Installing The Versalar 15000

    Chapter 2 Installing the Versalar 15000 This chapter describes how to install the Versalar 15000 chassis. It includes the following topics: Topic Page Preparing to Install the Versalar 15000 Installing the Versalar 15000 2-10 308684-B Rev 00...
  • Page 64: Preparing To Install The Versalar 15000

    Your installation site meets the physical, electrical, and environmental requirements. The sections that follow provide information to help you prepare for installation. Caution: The Versalar 15000 is intended for use in a restricted access loca- tion. Verifying Shipment Contents Inspect all items for shipping damage. If you detect any damage, do not install the Versalar 15000.
  • Page 65 • One null modem crossover adapter • One 10-foot console serial cable Bracket kit containing: Mount the Versalar 15000 in an • Two angle brackets equipment rack. • Ten cagenut screws with washers (Use the cagenuts only if the •...
  • Page 66: Figure 2-1. Accessories In The Versalar 15000 Shipping Container

    Installing and Maintaining the Versalar Switch Router 15000 Figure 2-1 illustrates the accessories in the Versalar 15000 shipping container. ESD wrist strap Console cable (DB-9 receptacle to DB-25 plug cable) Console cable (DB-9 receptacle to DB-9 -receptacle cable) DB-25 receptacle...
  • Page 67: Supplying Equipment

    Installing the Versalar 15000 Supplying Equipment You might need items that are not included in the Versalar 15000 accessory package. Before installing the Versalar 15000 hardware, ensure that you have all the cables, tools, and other equipment that you need.
  • Page 68: Hardware For Mounting The Versalar 15000 In An Equipment Rack

    Figure 2-2. SC Duplex to SC Duplex Cable Hardware for Mounting the Versalar 15000 in an Equipment Rack To install the Versalar 15000 in an equipment rack, you need a Phillips screwdriver and a rack that meets the following specifications: •...
  • Page 69: Verifying Site Requirements

    Ensure that the installation site meets the space, electrical, and environmental requirements listed in this section. See Appendix A, “Technical Specifications,” for more information. Space Requirements The installation site must provide sufficient free space around the Versalar 15000 to ensure proper ventilation and access for servicing (Table 2-3).
  • Page 70: Dc Input Electrical Requirements

    Installing and Maintaining the Versalar Switch Router 15000 Table 2-5 lists the wall receptacle requirements for AC power. Table 2-5. Wall Receptacle Requirements for AC Power Country Receptacle Voltage United States and National Electrical Manufacturers Association 180-264 V Canada (NEMA) L6-20R locking receptacle VRS0120A Any other country Your Versalar distributor attaches the necessary...
  • Page 71: Environmental Requirements

    Installing the Versalar 15000 Environmental Requirements The installation site must meet the following environmental requirements (Table 2-7). Table 2-7. Environmental Requirements Altitude Humidity Temperature 0-10,000 ft (0-3048 m) 5%-85%, noncondensing 41°-104°F (5°-40°C), stable 308684-B Rev 00...
  • Page 72: Installing The Versalar 15000

    Installing and Maintaining the Versalar Switch Router 15000 Installing the Versalar 15000 When you are ready to install the Versalar 15000, you can do one of the following: • Position the Versalar 15000 on a flat, sturdy, horizontal surface. •...
  • Page 73 Installing the Versalar 15000 To ensure proper ventilation, make sure that there is at least 4 in. (10.16 cm) of space between the platforms. Figure 2-3 shows three DC power-based platforms as well as two AC power-based platforms installed in four-post racks.
  • Page 74: Figure 2-3. Three Versalar 15000 Dc Platforms And Two Ac Platforms In A Four-Post Rack

    Installing and Maintaining the Versalar Switch Router 15000 4 in. (10.15 cm) min. 4 in. (10.15 cm) min. 4 in. (10.15 cm) min. VRS0117A Figure 2-3. Three Versalar 15000 DC Platforms and Two AC Platforms in a Four-Post Rack 2-12 308684-B Rev 00...
  • Page 75: Mounting The Versalar 15000 In A 19-Inch Rack

    (Figure 2-4). Holding the Versalar 15000 in position, align the flanged end of each bracket with two holes on each side of the vertical rack support. It is easiest to complete this step with two people. Make sure that the hole pairs on either side of the vertical support match horizontally.
  • Page 76: Figure 2-4. Attaching Angle Brackets In A 19-Inch Rack

    Installing and Maintaining the Versalar Switch Router 15000 Height 27 in. (68.6 cm) minimum Depth 20 in. (50.8 cm) minimum Screws (2 places) Bracket (2 places) Rail without threaded holes Cage nut BAC0054A Figure 2-4. Attaching Angle Brackets in a 19-Inch Rack 2-14 308684-B Rev 00...
  • Page 77: Figure 2-5. Installing The Versalar 15000 In A 19-Inch Four-Post Rack

    Installing the Versalar 15000 VRS0055A Figure 2-5. Installing the Versalar 15000 in a 19-Inch Four-Post Rack 2-15 308684-B Rev 00...
  • Page 78: Mounting The Versalar 15000 In An Optional 23-Inch Rack

    If the holes in the rack’s vertical supports are not threaded for cagenut screws, insert a cagenut in five locations. Holding the Versalar 15000 in position, align the flanges with two holes on each side of the vertical rack support (Figure 2-8).
  • Page 79: Figure 2-6. Attaching Angle Brackets In A 23-Inch Rack

    Installing the Versalar 15000 Height 27 in. (68.6 cm) minimum Depth 20 in. (50.8 cm) minimum Screws (2 places) Bracket (2 places) Rail without threaded holes Cage nut BAC0070A Figure 2-6. Attaching Angle Brackets in a 23-Inch Rack 2-17 308684-B Rev 00...
  • Page 80 Installing and Maintaining the Versalar Switch Router 15000 Screws (8 places) Side view Standard 4-post rack position Standard 2-post rack position Reversed 2-post rack position Possible locations to reposition flanges (3) VRS0071A Figure 2-7. Repositioning the Vertical Flanges for Either a Two- or Four-Post Rack 2-18 308684-B Rev 00...
  • Page 81: Figure 2-8. Installing The Versalar 15000 In A 23-Inch Four-Post Rack

    Installing the Versalar 15000 VRS0072A Figure 2-8. Installing the Versalar 15000 in a 23-Inch Four-Post Rack 2-19 308684-B Rev 00...
  • Page 82: Mounting The Versalar 15000 In A Two-Post Rack

    Installing and Maintaining the Versalar Switch Router 15000 Mounting the Versalar 15000 in a Two-Post Rack To mount the Versalar 15000 in a two-post rack, you need the following equipment: • A standard 19-inch equipment rack. If the rack does not have threaded rail holes, you must attach the 8 cagenuts shipped with the Versalar 15000.
  • Page 83: Figure 2-9. Repositioning The Vertical Flanges In A Two-Post Rack

    Installing the Versalar 15000 Screws (8 places) VRS0013A Figure 2-9. Repositioning the Vertical Flanges in a Two-Post Rack 2-21 308684-B Rev 00...
  • Page 84 Installing and Maintaining the Versalar Switch Router 15000 Ensure that the slots in the Versalar 15000 flanges align with the holes in the rack. If the holes in the rack’s vertical supports are not threaded for cagenut screws, insert a cagenut in 8 locations. (See Figure 2-9.)
  • Page 85: Figure 2-10. Installing The Versalar 15000 In A Two-Post Rack

    Installing the Versalar 15000 VRS0068A Figure 2-10. Installing the Versalar 15000 in a Two-Post Rack 2-23 308684-B Rev 00...
  • Page 87: Installing Power Supplies

    AC power unit. The Versalar 15000 contains one or two DC-input power modules (see Figure 3-1 on page 3-2). The Versalar 15000 ships with a single DC power module installed in the right power module slot. You can install a second power module for redundancy and high-availability operation. 308684-B Rev 00...
  • Page 88 Installing and Maintaining the Versalar Switch Router 15000 Figure 3-1 shows a DC input power module. VRS0010A Figure 3-1. Versalar 15000 DC Power Module Table 3-1 describes the DC power module LEDs. Table 3-1. DC Power Module LEDs State Meaning DC Output No output is present.
  • Page 89: Figure 3-2. Front And Rear Views Of The Versalar 15000 With Two Optional Ac Power Modules

    However, if necessary, you can use two AC units with one DC unit. Front of chassis Rear of chassis AC power supply modules AC power supply modules VRS0144A Figure 3-2. Front and Rear Views of the Versalar 15000 with Two Optional AC Power Modules 308684-B Rev 00...
  • Page 90: Installing A Redundant Dc Power Module

    The operating system generates an event message in response to any change in the status of a power module. These messages identify the power module by its slot. From the front of the Versalar 15000, power module slot 1 is on the left, and power module slot 2 is on the right.
  • Page 91: Figure 3-3. Removing The Versalar 15000 Front Bezels

    Installing Power Supplies VRS0027A Figure 3-3. Removing the Versalar 15000 Front Bezels 308684-B Rev 00...
  • Page 92: Figure 3-4. Replacing The Versalar 15000 Front Bezels

    Align the mounting retainers on the inside of the bezel with the holes on the front of the chassis (Figure 3-4). Push the sides of the bezel into place. VRS0028A Figure 3-4. Replacing the Versalar 15000 Front Bezels 308684-B Rev 00...
  • Page 93: Removing And Installing A Power Filler Plate

    The purpose of the power filler plate is to maintain the proper cooling airflow in the Versalar 15000. If you remove a power module from the Versalar 15000 without replacing it, you must install a power filler plate. When you add a second power module, you must first remove the installed power filler plate from the redundant power slot.
  • Page 94: The Dc Power Module

    Installing and Maintaining the Versalar Switch Router 15000 Captive screws VRS0029A Figure 3-5. Removing or Installing a Power Filler Plate The DC Power Module To install a DC power module: Make sure that the circuit breaker is turned on. Verify that the input voltage cable is connected at the back of the chassis. Remove the bottom front bezel (see “Power Modules”...
  • Page 95 Versalar 15000 automatically redistributes the load between the two power modules. Replace the bezel (see “Power Modules” on page 3-1). If neither of the two LEDs on the power module turns on, contact the Nortel Networks Technical Solutions Center. 308684-B Rev 00...
  • Page 96: Removing A Dc Power Module

    Versalar 15000. You can remove an operational power module without affecting the operation of the Versalar 15000. When you remove a power module, the LEDs on the power module turn off, and the Versalar 15000 automatically redistributes the load to the remaining power module.
  • Page 97: Figure 3-6. Removing Or Installing A Dc Power Module

    Installing Power Supplies Captive screws VRS0020A Figure 3-6. Removing or Installing a DC Power Module 3-11 308684-B Rev 00...
  • Page 98: Connecting To The Dc Power Source

    Danger: Due to high-energy hazards, only qualified service personnel are permitted to connect the Versalar 15000 to the DC power source. The Versalar 15000 supports two DC power supply modules. The second power supply module provides redundancy. To operate in redundant mode, both circuit breakers must be in the on (1) position.
  • Page 99: Figure 3-7. Terminal Block And Circuit Breakers On The Back Of The Versalar 15000

    Installing Power Supplies To connect the Versalar 15000 to the DC power source: Make sure that both circuit breakers on the Versalar 15000 are in the off (0) position (Figure 3-7). VRS0124A Figure 3-7. Terminal Block and Circuit Breakers on the Back of the...
  • Page 100: Figure 3-8. Dc Power Terminal Block And Power Switch

    Installing and Maintaining the Versalar Switch Router 15000 Using a Phillips screwdriver, remove the 2 screws that secure the terminal block cover to the power module (Figure 3-8). Terminal block cover VRS0052A Figure 3-8. DC Power Terminal Block and Power Switch 3-14 308684-B Rev 00...
  • Page 101: Figure 3-9. Removing The Strain Relief Bracket

    Installing Power Supplies Using a Phillips screwdriver, remove the 2 screws that secure the strain relief bracket to the terminal blocks (Figure 3-9). Strain relief bracket VRS0053A Figure 3-9. Removing the Strain Relief Bracket Using a 5/32 in. hex wrench, loosen the screws on the terminal blocks (Figure 3-10).
  • Page 102: Figure 3-10. Attaching The Dc Input Leads

    Strip 0.80 in. (20 mm) of insulation from the end of an AWG #2 or #4 wire. Note: Although AWG #4 wiring is adequate for the input leads, Nortel Networks recommends AWG #2 to ensure minimal voltage drop from the power source.
  • Page 103 Installing Power Supplies If you are connecting the Versalar 15000 to both power sources, repeat steps 4 through 9 for the other terminal blocks. Use the two terminal block sections on the right (Input B in Figure 3-7) to establish the connection to the second power source.
  • Page 104: Figure 3-11. Installing The Strain Relief Bracket

    VRS0053B Figure 3-11. Installing the Strain Relief Bracket Danger: After the Versalar 15000 is connected to the power source, do not remove the input leads. You must disconnect the Versalar 15000 from the power source before removing any wiring.
  • Page 105: Installing Optional Ac Power Module(S)

    These messages identify the power module by its slot. From the front of the Versalar 15000, the AC power module slot 1 is on the left, and power module slot 2 is on the right.
  • Page 106: Installing An Ac Power Module

    Installing and Maintaining the Versalar Switch Router 15000 VRS0134A Figure 3-12. Mounting the Separate AC Power Unit Installing an AC Power Module To install an AC power module in the separate AC power unit: Ensure that the circuit breaker is turned on. Verify that the input voltage cable is connected at the back of the chassis.
  • Page 107 Installing Power Supplies For instructions, see “Removing an AC Power Module” on page 3-22. Grasp the handle of the replacement module with one hand and the power supply handle with the other (Figure 3-13). Power supply handle Captive screw Power supply handle VRS0126A Figure 3-13.
  • Page 108: Removing An Ac Power Module

    LEDs on the power module turn on. At the same time, the Versalar 15000 automatically redistributes the load between the two power modules. If neither of the two LEDs on the power module turns on, contact the Nortel Networks Technical Solutions Center. Removing an AC Power Module...
  • Page 109: Connecting To The Optional Ac Power Module(S)

    Installing Power Supplies Connecting to the Optional AC Power Module(s) AC input power is an optional feature of the Versalar 15000. This option ships with a shelf ready for installation into a 19-inch-wide rack. You can install an additional, redundant power unit in the same shelf. (See Installing an External AC Power Unit.)
  • Page 110: Figure 3-14. Two Versalar 15000 Platforms With The Ac Power Unit In A

    Installing and Maintaining the Versalar Switch Router 15000 C power unit 4 in. (10.15 cm) min. C power unit VRS0140A Figure 3-14. Two Versalar 15000 Platforms with the AC Power Unit in a Four-Post Rack 3-24 308684-B Rev 00...
  • Page 111 Connect the AC power unit to the DC terminal block (see pages 3-12 3-19). Connect the AC management cable from the 9-pin D-sub connector on the back of the Versalar 15000 to the separate AC power unit (Figure 3-15). . Note: The chassis must be grounded (see Step 11. on...
  • Page 112: Figure 3-15. Ac Management Cable Location

    Installing and Maintaining the Versalar Switch Router 15000 Grounding Groundin stud wire management cable External AC power supply Figure 3-15. AC Management Cable Location Insert the power plugs on the back of the separate AC power unit into the appropriate power outlet. (See Table 2-5 on page 2-8). Each power supply requires one power cord.
  • Page 113: Installing Processor And Interface Cards And Connecting Equipment

    Chapter 4 Installing Processor and Interface Cards and Connecting Equipment This chapter provides instructions for adding and replacing Versalar 15000 processor and interface cards. It also discusses connecting communications cables and connecting console and modem equipment. It includes the following topics:...
  • Page 114: Location Of The Processor And Interface Cards

    Installing and Maintaining the Versalar Switch Router 15000 Location of the Processor and Interface Cards Figure shows the location of the processor and interface cards. Refer to Chapter 1 for descriptions of configurations of these cards. Access interface cards AP cards SSP interface IFP cards console card...
  • Page 115: Attaching The Antistatic Wrist Strap

    Installing Processor and Interface Cards and Connecting Equipment Attaching the Antistatic Wrist Strap The Versalar 15000 ships with an antistatic wrist strap. The antistatic wrist strap directs the discharge of static electricity from your body to the chassis of the router, thereby avoiding discharge to, and possible damage of, sensitive electronic components.
  • Page 116: Figure 4-2. Connecting The Wrist Strap Jack To The Front Ground Clip

    Installing and Maintaining the Versalar Switch Router 15000 VRS0015A Figure 4-2. Connecting the Wrist Strap Jack to the Front Ground Clip 308684-B Rev 00...
  • Page 117: Figure 4-3. Connecting The Wrist Strap Jack To The Back Ground Clip

    Installing Processor and Interface Cards and Connecting Equipment VRS0075A Figure 4-3. Connecting the Wrist Strap Jack to the Back Ground Clip 308684-B Rev 00...
  • Page 118: Installing And Replacing A Processor Card

    You can remove a processor card with the power on or off. Caution: Do not operate the Versalar 15000 with an empty processor card slot. If you need to replace a failed processor card and you do not yet have a replacement card, leave the failed processor card installed or install an air flow module as originally shipped with the chassis.
  • Page 119: Figure 4-4. Removing A Processor Card

    Installing Processor and Interface Cards and Connecting Equipment Captive Card screws handles VRS0023A Figure 4-4. Removing a Processor Card Pull on both card handles until the processor card ejects from the chassis. Rest the edge of the processor card on the palm of one hand, and with the other hand, pull the card out of the chassis.
  • Page 120: Installing A Processor Card

    Installing a Processor Card You can install a processor card with the power on or off. Caution: Electrostatic discharge can damage hardware. Attach the antistatic wrist strap before handling any Versalar 15000 components. To install a processor card: Attach the antistatic wrist strap.
  • Page 121: Figure 4-5. Processor Card Slots (Front Of Chassis)

    Installing Processor and Interface Cards and Connecting Equipment AP cards IFP cards SSP cards TP cards 10 11 12 Figure 4-5. Processor Card Slots (Front of Chassis) 308684-B Rev 00...
  • Page 122 Installing and Maintaining the Versalar Switch Router 15000 Holding the processor card by its top and bottom edges, orient the card so that the EMI card shield is on the left (Figure 4-6). card shield VRS0017A Figure 4-6. Positioning a Processor Card Align the processor card with the chassis slot arrows above and below the card slot.
  • Page 123: Figure 4-7. Installing A Processor Card

    VRS0024A Figure 4-7. Installing a Processor Card Insert the card until its connector panel touches the Versalar 15000 back panel. Press both card handles in at the same time until the card moves further into the chassis. Using a flat-tip screwdriver, tighten the 2 captive screws to secure the processor card to the chassis.
  • Page 124: Installing And Removing An Interface Card

    You can remove an interface card with the power on or off. Caution: Do not operate the Versalar 15000 with an empty interface card slot. If you need to replace a failed interface card and you do not yet have a replacement card, leave the failed interface card installed or install an air flow module.
  • Page 125: Figure 4-8. Removing An Interface Card

    Installing Processor and Interface Cards and Connecting Equipment Captive Card screws handles VRS0019A Figure 4-8. Removing an Interface Card Pull on both card handles until the interface card begins to come out of the chassis. Rest the edge of the interface card on the palm of one hand, and with the other hand, pull the card out of the chassis.
  • Page 126: Installing An Interface Card

    Installing an Interface Card You can install an interface card with the power on or off. Caution: Electrostatic discharge can damage hardware. Attach the antistatic wrist strap before handling any Versalar 15000 components. To install an interface card: Attach the antistatic wrist strap.
  • Page 127: Figure 4-9. Interface Card Slots (Back Of Chassis)

    Installing Processor and Interface Cards and Connecting Equipment T3 interface cards SSP interface console card Optional interface Trunk interface card Ethernet cards card 12 11 10 9 VRS0039A Figure 4-9. Interface Card Slots (Back of Chassis) 4-15 308684-B Rev 00...
  • Page 128 Align the interface card with the chassis slot arrows above and below the card slot. Holding the card handles open, slide the interface card into the slot using the card guides (Figure 4-11). Insert the card until its connector panel touches the Versalar 15000 back panel. 4-16 308684-B Rev 00...
  • Page 129: Figure 4-11. Installing An Interface Card

    Installing Processor and Interface Cards and Connecting Equipment Captive Card screws handles VRS0019B Figure 4-11. Installing an Interface Card Press both card handles in at the same time until the card moves further into the chassis. Using a flat-tip screwdriver, tighten the 2 captive screws to secure the interface card to the chassis.
  • Page 130: Connecting Console Equipment

    Installing and Maintaining the Versalar Switch Router 15000 Connect the cables to the card. For instructions, see “Connecting Communications Cables” on page 4-19 “Connecting Console Equipment” on page 4-25. Note: The chassis contains a hot-swap switch integrated in the ejector lever. Ensure that both captive fasteners are tight for proper operation.
  • Page 131: Connecting Communications Cables

    Installing Processor and Interface Cards and Connecting Equipment Connecting Communications Cables Gather the communications equipment and cables that you will attach to the Versalar 15000. If you do not have the proper cables, contact your network administrator. This section includes the following topics:...
  • Page 132: Connecting To An Ethernet Interface

    Installing and Maintaining the Versalar Switch Router 15000 Connecting to an Ethernet Interface The SSP interface Ethernet card provides a 10BASE-T UTP port. To connect a UTP cable to the 10BASE-T port, insert the cable into the RJ-45 receptacle connector (Figure 4-12).
  • Page 133: Connecting To An Oc-12C/Stm-4C Or An Oc-3 Atm Access Interface

    Installing Processor and Interface Cards and Connecting Equipment Connecting to an OC-12c/STM-4c or an OC-3 ATM Access Interface To connect to an OC-12c/STM-4c or an OC-3 ATM access interface, insert the fiber optic cable into the connector on the OC-12c/STM-4c or Dual OC-3 (SM or MM) ATM access interface card (Figure 4-13).
  • Page 134: Connecting To A T3 Interface

    Installing and Maintaining the Versalar Switch Router 15000 Connecting to a T3 Interface Figure 4-14 shows the transmit and receive connector pairs for each of the six ports on a T3 interface card. Rear of chassis T3 interface card slots 1 through 4 for redundant configuration slots 1 through 5 for non-redundant configuration Stat T3 Interface...
  • Page 135: Figure 4-15. Connecting A Coaxial Cable To The T3 Interface Card

    Installing Processor and Interface Cards and Connecting Equipment To lock a coaxial cable to the T3 connector: Gently push the coaxial cable onto the T3 connector (Figure 4-15). Turn the coaxial cable to the left until the key on the T3 connector clicks into the notch on the coaxial cable.
  • Page 136: Connecting To An Alarm

    Installing and Maintaining the Versalar Switch Router 15000 Connecting to an Alarm You can connect an alarm to the Versalar 15000 using the SSP interface Ethernet and the SSP interface console cards. The major and minor alarms provide connection to normally open (NO) and normally closed (NC) relay contacts.
  • Page 137: Connecting Console Equipment

    You use the Bay Command Console (BCC) to customize your Versalar 15000 configuration (for example, by editing IP parameters). To establish a local BCC session, you must connect the Versalar 15000 to a PC or to a VT-100 console. Complete the steps in one of the following sections:...
  • Page 138 Installing and Maintaining the Versalar Switch Router 15000 When you have the correct equipment, complete the following steps: Turn on and configure a comm port on the PC, using the parameters in Table 4-1. Refer to the PC user manual for instructions. Table 4-1.
  • Page 139: Figure 4-17. Connecting The Console Cable To A Pc With A 25-Pin Comm Port

    Installing Processor and Interface Cards and Connecting Equipment Rear of chassis SSP-C interface console card slot 10 SSP Interface Cosole Alarm Mute Alarm 25-pin Comm port Console Console cable Optional standard AT serial cable with 25-pin connectors Alarm Min NO Min COM Null modem adapter Min NC...
  • Page 140 Installing and Maintaining the Versalar Switch Router 15000 Attach one end of the null modem crossover adapter to the 25-pin plug connector on the console cable, then tighten the screws (Figure 4-18). Console cable connector Null modem crossover adapter Screw receptacle Rotate to tighten screw BAC0041A Figure 4-18.
  • Page 141: Connecting A Terminal With A 25-Pin Comm Port To The Console Port

    (Order No. 110307) • Null modem crossover adapter with two 25-pin receptacle connectors (Order No. 110308) To connect a terminal to the Versalar 15000: Turn on and configure the terminal, using the parameters in Table 4-2. Refer to the terminal user manual for instructions.
  • Page 142: Figure 4-19. Connecting A Console Cable To A Terminal With A 25-Pin Comm Port

    Installing and Maintaining the Versalar Switch Router 15000 Insert the 9-pin receptacle end of the console cable into the console connector on the SSP interface console card (Figure 4-19). Rear of chassis SSP-C interface console card slot 10 SSP Interface Cosole Alarm Mute...
  • Page 143: Connecting A Pc With A 9-Pin Comm Port To The Console Port

    Connecting a PC with a 9-pin Comm Port to the Console Port To connect a PC to the console port, you need the following item, which is shipped with the Versalar 15000: • Serial console cable with 9-pin receptacle connectors (Order No.
  • Page 144: Connecting A Modem

    4-20). Connecting a Modem If you need remote dial-in access to the BCC, you can connect a modem (AT or Hayes compatible) to the Versalar 15000 SSP card using the console cable shipped with the Versalar 15000. 4-32 308684-B Rev 00...
  • Page 145 Installing Processor and Interface Cards and Connecting Equipment To connect a modem to the Versalar 15000: Turn on and configure the modem, using the parameters in Table 4-4. Refer to the modem documentation for instructions. Table 4-4. Modem Settings Setting...
  • Page 146: Figure 4-21. Connecting A Modem To The Versalar 15000

    SQUEEZE TO REMOVE BAC0043A Figure 4-21. Connecting a Modem to the Versalar 15000 Insert the 25-pin plug connector at the other end of the console cable into the modem’s RS-232 data communications port. Two SSP cards, each with a modem, can share the same dial-up line (Figure 4-22).
  • Page 147: Figure 4-22. Dual Modem Access With A Single Telco Line

    Installing Processor and Interface Cards and Connecting Equipment Telco RJ-11 RJ-11 Telco Phone Modem 2 Stat Run Mstr Stat Run Mstr Temp Fan Maj Min Temp Fan Maj Min Diag Test Count Diag Test Count Modem Modem SQUEEZE TO REMOVE SQUEEZE TO REMOVE Boot Flash Boot Flash...
  • Page 149: Operating The Versalar 15000

    Chapter 5 Operating the Versalar 15000 This chapter describes some of the routine tasks of operating the Versalar 15000. It includes the following topics: Topic Page Verifying a Successful Installation Turning the Versalar 15000 On and Off Resetting the Versalar 15000...
  • Page 150: Verifying A Successful Installation

    Installing and Maintaining the Versalar Switch Router 15000 Verifying a Successful Installation After connecting the Versalar 15000 to the network, you can verify a successful installation by checking the LEDs on the processor and interface cards. When you turn on the Versalar 15000, the following sequence of processor and interface card LEDs should occur: The power LEDs light green when the Versalar 15000 is turned on.
  • Page 151: Turning The Versalar 15000 On And Off

    Operating the Versalar 15000 Turning the Versalar 15000 On and Off The following instructions are for a Versalar 15000 with a DC power source and for a Versalar 15000 with the AC power unit installed. Turning the Versalar 15000 with a DC Power Source On and Off...
  • Page 152: Turning The Versalar 15000 With The Ac Power Unit On And Off

    Verify that air is flowing from the cooling fans out through the top of the Versalar 15000. If you cannot feel air flow from the Versalar 15000 vents, or if the power output LED remains off, do the following: Turn the power switch on the front of the Versalar 15000 to the off (0) position.
  • Page 153: Resetting The Versalar 15000

    VRS0047A Figure 5-2. Versalar 15000 Reset Switch You can use the Reset switch to reboot the Versalar 15000 hardware without cycling power. To warm-start the Versalar 15000 (no diagnostic tests run), press the Reset switch for less than 5 seconds.
  • Page 154: Muting An Alarm

    Installing and Maintaining the Versalar Switch Router 15000 Muting an Alarm An alarm mute button is located on the SSP interface Ethernet card and the SSP interface console card. Figure 5-3 shows the location of the alarm mute button on the SSP interface console card.
  • Page 155: Removing Flash Or Option Memory Cards From The Ssp Card

    Operating the Versalar 15000 Removing Flash or Option Memory Cards from the SSP Card To remove flash or option memory cards from the SSP card: Remove the memory card access cover by squeezing the sides of the cover at the top and bottom (Figure 5-4).
  • Page 156: Figure 5-5. Removing A Flash Or Option Memory Card

    Installing and Maintaining the Versalar Switch Router 15000 Press the eject button above the memory card receptacle on the SSP card (Figure 5-5). The card pops out slightly. Eject button BAC0031A Figure 5-5. Removing a Flash or Option Memory Card Pull the memory card out of the card receptacle.
  • Page 157: Installing Flash Or Option Memory Cards In The Ssp Card

    Gently push the card in until it fits snugly in place. If the memory card is new and you did not obtain it from Nortel Networks, you must format the card before attempting to write to it. See Managing and Troubleshooting Carrier Networking Services for instructions.
  • Page 158: Protecting Memory Card Files

    Installing and Maintaining the Versalar Switch Router 15000 Protecting Memory Card Files Nortel Networks ships each memory card with its read-write protect switch in the unprotected position. After successfully loading the configuration file and saving your configuration, you might want to write-protect the memory card for backup purposes.
  • Page 159: Figure 5-7. Memory Card Read-Write Protect Switch

    Operating the Versalar 15000 Unprotected Protected 6948 Figure 5-7. Memory Card Read-Write Protect Switch Adjust the read-write protect switch. Reinsert the memory card into the card receptacle (Figure 5-6 on page 5-9): Position the card with the label facing to the left and the insert arrow pointing toward the card receptacle.
  • Page 161: Technical Specifications

    Appendix A Technical Specifications This appendix provides physical, electrical, and environmental specifications for the Versalar 15000, descriptions of the interface options, and specifications for the OC-12c/STM-4c ATM and DS3 interface cards. 308684-B Rev 00...
  • Page 162: Physical, Electrical, And Environmental Specifications

    Installing and Maintaining the Versalar Switch Router 15000 Physical, Electrical, and Environmental Specifications The physical dimensions and weight of the Versalar 15000 with fan tray and two power supplies are as follows: • Height: 22.75 in. (75.56 cm) • Width: 17.25 in. (43.81 cm) •...
  • Page 163: Ethernet 10/100Base-T Interface

    Technical Specifications Ethernet 10/100BASE-T Interface The Ethernet 10/100BASE-T interface on the SSP interface Ethernet card provides UTP support for LAN connectivity. Table A-1 identifies the pin locations and function assignments for this interface. Table A-1. 10/100BASE-T Interface Pin Assignments Standard Interface Signal Pin Assignment Pin No.
  • Page 164: Local Console Interface

    The SSP interface console card contains one console service interface, labeled Console; its DB-9 plug connector provides an RS-232-D serial connection. You use this local console port to connect the Versalar 15000 to any VT-100-compatible console device for direct console access.
  • Page 165: Service Modem Interface

    The SSP card has one modem service interface, labeled Modem; its DB-9 plug connector provides an RS-232-D serial connection. You use this local modem port to connect the Versalar 15000 to any Hayes-compatible modem for remote dial-in access. The Versalar 15000 shipping package includes the console/modem cable for connecting devices to the modem port.
  • Page 166: Oc-12C/Stm-4C Atm Interface Card Specifications

    Installing and Maintaining the Versalar Switch Router 15000 OC-12c/STM-4c ATM Interface Card Specifications The OC-12c/STM-4c ATM interface card provides the Versalar 15000 with a 622 Mb/s ATM interface. This connection is concatenated, which provides for increased efficiency by eliminating the need to partition the bandwidth.
  • Page 167: Ds3 Interface Card Specifications

    Technical Specifications DS3 Interface Card Specifications The DS3 port adapter’s T3 port is designed to receive and transmit at the DSX-3 level while driving and receiving from a 75-ohm coaxial cable (ATT 728A type coax). The T3 port connects directly to any equipment with DSX-3 level BNC connectors.
  • Page 169: Versalar 15000 Card Glossary

    Access Interface Supports network layer processing for access processor (AP) cards. In the Card Versalar 15000, it occupies slots 1 to 5 in the back of the chassis and includes: • Hex T3 (T3) cards • Access redundancy module (ARM) cards •...
  • Page 170: Interface Card

    Processor (ATP) variable bit rate (VBR) service and unspecified bit rate (UBR) service. The Card Versalar 15000 can support two ATP cards in slots 11 and 12 in the front of the chassis. Channelized Identifies a certain type of processor card. The Versalar 15000 supports three...
  • Page 171 Identifies the 2-slot PCMCIA located on the SSP card that permits the installation of option cards. Processor Card Occupies slots 1 to 12 in the front of the Versalar 15000 and includes the following types of cards: • AP cards •...
  • Page 172 Installing and Maintaining the Versalar Switch Router 15000 SSP Interface Occupies slot 10 in the back of the chassis. Console Card SSP Interface Supports the 10/100 Mb Ethernet interface. It occupies slot 9 in the back of the Ethernet Card chassis.
  • Page 173 Index Numbers to terminal console, 4-29 10/100BASE-T interface, connecting to, 4-20 console/modem, 2-3 fiber optic to OC-12c/STM-4c interface, 4-21 ordering, 2-5 CAP (channelized access processor) card AC power module description, 1-4 description, 3-1 installing and replacing, 4-6 status LEDs, 3-2 status LEDs, 1-9 acronyms, xviii cards.
  • Page 174 SSP card description, 1-16 hardware installing and replacing, 4-6 requirements, 2-6 SSP interface console card shipped with the Versalar 15000, 2-2 installing and replacing, 4-12 heat dissipation, ensuring, 2-7 SSP interface Ethernet card description, 1-34 installing and replacing, 4-12 T3 interface card...
  • Page 175 RS-232 connections installing, 5-9 console (service) interface, A-4 removing, 5-7 service modem interface, A-5 PC console, connecting to Versalar 15000, 4-25 to 4-28 shipment contents, verifying, 2-2 physical specifications, A-2 site requirements, 2-7 pin assignments space requirements, 2-7...
  • Page 176 4-22 installing and replacing, 4-12 status LEDs, 1-26, 1-30, 1-31 technical specifications, A-7 technical support, xx terminal console, connecting to Versalar 15000, 4-29 text conventions, xviii TP (trunk processor) card description, 1-18 installing and replacing, 4-6 status LEDs, 1-20, 1-23...