IBM System x iDataPlex dx360 M4 7912 Service Manual page 90

Problem determination
Table of Contents

Advertisement

800b050a-1e81ffff • 806f0007-0302ffff
800b050a-1e81ffff
Non-redundant:Insufficient
Resources for
[RedundancySetElementName] has
asserted. (Cooling Zone)
Explanation: This message is for the use case when
a Redundancy Set has transitioned to
Non-redundant:Insufficient Resources.
Internal Event: No
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0810
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Make sure that the connectors on fan n are not
damaged.
2.
Make sure that the fan n connectors on the system
board are not damaged.
3.
Make sure that the fans are correctly installed.
4.
Reseat the fans.
5.
Replace the fans. (n = fan number)
800b050c-2581ffff
Non-redundant:Insufficient
Resources for
[RedundancySetElementName] has
asserted. (Backup Memory)
Explanation: This message is for the use case when
a Redundancy Set has transitioned to
Non-redundant:Insufficient Resources.
Internal Event: No
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0810
SNMP Trap ID: 41
Automatically notify Support: No
User response:
1.
Check the system-event log for DIMM failure events
(uncorrectable or PFA) and correct the failures.
2.
Re-enable mirroring in the Setup utility.
806f0007-0301ffff
[ProcessorElementName] has
Failed with IERR. (CPU 1)
Explanation: This message is for the use case when
an implementation has detected a Processor Failed -
IERR Condition.
72
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Internal Event: No
Severity: Error
Alert Category: Critical - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0042
SNMP Trap ID: 40
Automatically notify Support: No
User response:
1.
Update the latest level of system firmware and
device drivers are installed for all adapters and
standard devices, such as UEFI, IMM Ethernet,and
SAS. Important: Some cluster solutions require
specific code levels or coordinated code updates. If
the device is part of a cluster solution, verify that the
latest level of code is supported for the cluster
solution before you update the code.
2.
Run the DSA program.
3.
Reseat the adapter.
4.
Replace the adapter.
5.
(Trained technician only) Replace microprocessor
n. (n = microprocessor number)
6.
(Trained technician only) Replace the system
board.
806f0007-0302ffff
[ProcessorElementName] has
Failed with IERR. (CPU 2)
Explanation: This message is for the use case when
an implementation has detected a Processor Failed -
IERR Condition.
Internal Event: No
Severity: Error
Alert Category: Critical - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0042
SNMP Trap ID: 40
Automatically notify Support: No
User response:
1.
Update the latest level of system firmware and
device drivers are installed for all adapters and
standard devices, such as UEFI, IMM Ethernet,and
SAS. Important: Some cluster solutions require
specific code levels or coordinated code updates. If
the device is part of a cluster solution, verify that the
latest level of code is supported for the cluster
solution before you update the code.
2.
Run the DSA program.
3.
Reseat the adapter.
4.
Replace the adapter.

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x idataplex dx360 m4 7913

Table of Contents