IBM System x iDataPlex dx360 M4 7912 Service Manual page 40

Problem determination
Table of Contents

Advertisement

I.3048005 • I.580A6
I.3048005
[I.3048005] UEFI has booted from the
backup flash bank.
Explanation: Booting Backup UEFI Image
Severity: Info
User response: Complete the following steps:
1.
Refer to service information for this product section
on UEFI Recovery to return system to primary bank.
I.3808004
[I.3808004] The IMM System Event log
(SEL) is full.
Explanation: IPMI System Event Log is Full
Severity: Info
User response: Complete the following steps:
1.
Use IMM Web Interface to clear event log.
2.
If IMM communication is unavailable, use F1 Setup
to access System Event Logs Menu and Choose
Clear IMM System Event Log and Restart Server.
I.3818001
[I.3818001] The firmware image capsule
signature for the currently booted flash
bank is invalid.
Explanation: Current Bank CRTM Capsule Update
Signature Invalid
Severity: Info
User response: Complete the following steps:
1.
Reboot system. Will come up on backup UEFI
image. Reflash the primary UEFI image.
2.
If error does not persist no additional recovery
action is required.
3.
If error persists, or boot is unsuccessful, (Trained
service technician only) Replace the system board.
I.3818002
[I.3818002] The firmware image capsule
signature for the non-booted flash
bank is invalid.
Explanation: Opposite Bank CRTM Capsule Update
Signature Invalid
Severity: Info
User response: Complete the following steps:
1.
Reflash backup UEFI image.
2.
If error does not persist no additional recovery
action is required.
3.
If error persists, or boot is unsuccessful, (Trained
service technician only) Replace the system board.
22
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
I.3818003
[I.3818003] The CRTM flash driver
could not lock the secure flash region.
Explanation: CRTM Could not lock secure flash
region
Severity: Info
User response: Complete the following steps:
1.
If system failed to boot successfully, DC cycle
system.
2.
If system boots to F1 setup, flash UEFI image and
reset bank to primary (if required). If system boots
without error, recovery is complete and no additional
action is required.
3.
If system fails to boot, or if flash attempt fails,
(Trained service technician only) Replace the
system board.
I.58015
[I.58015] Memory spare copy initiated.
Explanation: Spare Copy Started
Severity: Info
User response: Complete the following steps:
1.
No user required for this event. This is for
informational purposes only.
I.580A4
[I.580A4] Memory population change
detected.
Explanation: DIMM Population Change Detected
Severity: Info
User response: Complete the following steps:
1.
Check system event log for uncorrected DIMM
failures and replace those DIMMs.
I.580A5
[I.580A5] Mirror Fail-over complete.
DIMM number % has failed over to to
the mirrored copy.
Explanation: DIMM Mirror Fail-over Detected
Severity: Info
User response: Complete the following steps:
1.
Check the system-event log for uncorrected DIMM
failures and replace those DIMMs.
I.580A6
[I.580A6] Memory spare copy has
completed successfully.
Explanation: Spare Copy Complete
Severity: Info
User response: Complete the following steps:
1.
Check system log for related DIMM failures and
replace those DIMMs.