IBM System x iDataPlex dx360 M4 7912 Service Manual page 146

Problem determination
Table of Contents

Advertisement

81010901-1004ffff • 81010b01-0b01ffff
81010901-1004ffff
Numeric sensor
[NumericSensorElementName] going
high (upper critical) has deasserted.
(Riser 2B Temp)
Explanation: This message is for the use case when
an implementation has detected an Upper Critical
sensor going high has deasserted.
Internal Event: No
Severity: Info
Alert Category: Critical - Temperature
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0495
SNMP Trap ID: 0
Automatically notify Support: No
User response: No action; information only.
81010901-2701ffff
Numeric sensor
[NumericSensorElementName] going
high (upper critical) has deasserted.
(Ambient Temp)
Explanation: This message is for the use case when
an implementation has detected an Upper Critical
sensor going high has deasserted.
Internal Event: No
Severity: Info
Alert Category: Critical - Temperature
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0495
SNMP Trap ID: 0
Automatically notify Support: No
User response: No action; information only.
81010901-2c01ffff
Numeric sensor
[NumericSensorElementName] going
high (upper critical) has deasserted.
(Mezz Card Temp)
Explanation: This message is for the use case when
an implementation has detected an Upper Critical
sensor going high has deasserted.
Internal Event: No
Severity: Info
Alert Category: Critical - Temperature
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0495
SNMP Trap ID: 0
128
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Automatically notify Support: No
User response: No action; information only.
81010901-2d01ffff
Numeric sensor
[NumericSensorElementName] going
high (upper critical) has deasserted.
(PCH Temp)
Explanation: This message is for the use case when
an implementation has detected an Upper Critical
sensor going high has deasserted.
Internal Event: No
Severity: Info
Alert Category: Critical - Temperature
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0495
SNMP Trap ID: 0
Automatically notify Support: No
User response: No action; information only.
81010902-0701ffff
Numeric sensor
[NumericSensorElementName] going
high (upper critical) has deasserted.
Explanation: This message is for the use case when
an implementation has detected an Upper Critical
sensor going high has deasserted.
Internal Event: No
Severity: Info
Alert Category: Critical - Voltage
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0495
SNMP Trap ID: 1
Automatically notify Support: No
User response: If the specified sensor is SysBrd 12V,
SysBrd 3.3V or SysBrd 5V: No action; information only.
81010b01-0b01ffff
Numeric sensor
[NumericSensorElementName] going
high (upper non-recoverable) has
deasserted.
Explanation: This message is for the use case when
an implementation has detected an Upper
Non-recoverable sensor going high has deasserted.
Internal Event: No
Severity: Info
Alert Category: Critical - Temperature
Serviceable: No