806f0a0c-200fffff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 15)
Explanation: This message is for the use case when
an implementation has detected an Over Temperature
Condition for Memory that has been Detected.
Internal Event: No
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Make sure that the fans are operating, that there are
no obstructions to the airflow, that the air baffles are
in place and correctly installed, and that the server
cover is installed and completely closed.
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-2010ffff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 16)
Explanation: This message is for the use case when
an implementation has detected an Over Temperature
Condition for Memory that has been Detected.
Internal Event: No
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Make sure that the fans are operating, that there are
no obstructions to the airflow, that the air baffles are
in place and correctly installed, and that the server
cover is installed and completely closed.
2.
Make sure that ambient temperature is within the
specifications.
806f0a0c-200fffff • 81010002-0701ffff
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a13-0301ffff
A Fatal Bus Error has occurred
on system
[ComputerSystemElementName]. (CPU
1 PECI)
Explanation: This message is for the use case when
an implementation has detected a Bus Fatal Error.
Internal Event: No
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0244
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
(Trained technician only)Reseat the microprocessor,
and then restart the server.
2.
(Trained technician only)Replace microprocessor n.
(n = microprocessor number)
806f0a13-0302ffff
A Fatal Bus Error has occurred
on system
[ComputerSystemElementName]. (CPU
2 PECI)
Explanation: This message is for the use case when
an implementation has detected a Bus Fatal Error.
Internal Event: No
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0244
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
(Trained technician only)Reseat the microprocessor,
and then restart the server.
2.
(Trained technician only)Replace microprocessor n.
(n = microprocessor number)
81010002-0701ffff
Numeric sensor
[NumericSensorElementName] going
low (lower non-critical) has deasserted.
(CMOS Battery)
Explanation: This message is for the use case when
an implementation has detected a Lower Non-critical
123