IBM System x iDataPlex dx360 M4 7912 Service Manual page 339

Problem determination
Table of Contents

Advertisement

Installing a power supply cage in a 2U chassis
To install the power supply cage in a 2U chassis, complete the following steps.
Power supply cage
1. Insert the power supply cage into the rear of the chassis.
2. Slide into the chassis until the release latch clicks into place.
3. Install the 2U chassis fan assembly (see "Installing the 2U chassis fan
4. Install the 2U chassis fan-assembly top cover (see "Installing the 2U chassis
5. Install the power supply (see "Installing a power supply in a 2U chassis" on
6. Install the chassis in the iDataPlex rack (see "Installing the 2U chassis in a rack"
Removing the optional dual-port network adapter
Note: Filler panel must be installed even if you do not install a network adapter.
To remove the network adapter, complete the following steps:
1. Read the safety information that begins on page vii and "Installation guidelines"
2. Turn off the server and peripheral devices and disconnect all power cords.
3. If the system-board tray is installed in a chassis, remove it (see "Removing the
4. If an expansion enclosure is installed on the system-board tray, remove it (see
5. Loosen the screws and the captive screws on the network adapter from the
2U chassis
assembly" on page 290).
fan-assembly top cover" on page 283).
page 317).
on page 285).
on page 275.
system-board tray from a 2U chassis" on page 279).
"Removing a GPGPU enclosure" on page 281); otherwise, remove the
system-board tray cover (see "Removing the system-board tray cover" on page
280).
screw holes.
Release latch
Chapter 5. Removing and replacing server components
321