IBM System x iDataPlex dx360 M4 7912 Service Manual page 131

Problem determination
Table of Contents

Advertisement

User response: Make sure that DIMMs are installed
and following the memory population chart in the
system publication.
806f070c-200effff
Configuration Error for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 14)
Explanation: This message is for the use case when
an implementation has detected a Memory DIMM
configuration error has been corrected.
Internal Event: No
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0126
SNMP Trap ID: 41
Automatically notify Support: No
User response: Make sure that DIMMs are installed
and following the memory population chart in the
system publication.
806f070c-200fffff
Configuration Error for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 15)
Explanation: This message is for the use case when
an implementation has detected a Memory DIMM
configuration error has been corrected.
Internal Event: No
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0126
SNMP Trap ID: 41
Automatically notify Support: No
User response: Make sure that DIMMs are installed
and following the memory population chart in the
system publication.
806f070c-2010ffff
Configuration Error for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 16)
Explanation: This message is for the use case when
an implementation has detected a Memory DIMM
configuration error has been corrected.
Internal Event: No
806f070c-200effff • 806f072b-2101ffff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0126
SNMP Trap ID: 41
Automatically notify Support: No
User response: Make sure that DIMMs are installed
and following the memory population chart in the
system publication.
806f070c-2581ffff
Configuration Error for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (All
DIMMS)
Explanation: This message is for the use case when
an implementation has detected a Memory DIMM
configuration error has been corrected.
Internal Event: No
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0126
SNMP Trap ID: 41
Automatically notify Support: No
User response: Make sure that DIMMs are installed
and following the memory population chart in the
system publication. One of the DIMMs :
806f072b-2101ffff
A successful software or
firmware change was detected on
system
[ComputerSystemElementName]. (IMM
Promotion)
Explanation: This message is for the use case when
an implementation has detected a Successful Software
or Firmware Change.
Internal Event: No
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0450
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only. IMM
Recovery :
113
Chapter 3. Diagnostics

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x idataplex dx360 m4 7913

Table of Contents