IBM System x iDataPlex dx360 M4 7912 Service Manual page 83

Problem determination
Table of Contents

Advertisement

Internal Event: No
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0508
SNMP Trap ID:
Automatically notify Support: No
User response:
1.
Replace the power supply with higher rated power.
2.
Reduce the total power consumption by removing
newly added or unused option like drives or
adapters.
8007010f-2201ffff
Sensor [SensorElementName]
has transitioned from normal to
non-critical state. (GPT Status)
Explanation: This message is for the use case when
an implementation has detected a Sensor transitioned
to non-critical from normal.
Internal Event: No
Severity: Warning
Alert Category: Warning - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 60
Automatically notify Support: No
User response:
1.
Check the IBM support site for service bulletins or
firmware updates that apply to this GPT error.
2.
Set the UEFI setting DISK GPT Recovery to
Automatic.
3.
Replace the corrupt disk.
8007010f-2582ffff
Sensor [SensorElementName]
has transitioned from normal to
non-critical state. (I/O Resources)
Explanation: This message is for the use case when
an implementation has detected a Sensor transitioned
to non-critical from normal.
Internal Event: No
Severity: Warning
Alert Category: Warning - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 60
Automatically notify Support: No
8007010f-2201ffff • 80070201-0301ffff
User response: Complete the following step to solve
PCI I/O resource errors:
1.
Go to F1 Setup
2.
System Settings
3.
Device and I/O ports
4.
PCI 64 bit Resource and choose enable.
80070114-2201ffff
Sensor [SensorElementName]
has transitioned from normal to
non-critical state. (TPM Phy Pres Set)
Explanation: This message is for the use case when
an implementation has detected a Sensor transitioned
to non-critical from normal.
Internal Event: No
Severity: Warning
Alert Category: Warning - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 60
Automatically notify Support: No
User response:
1.
Complete the administrative tasks that require the
TPM physical presence switch to be in the ON
position.
2.
Restore the physical presence switch to the OFF
position.
3.
Reboot the system.
4.
(Trained technician only) If the error continues,
replace the planar.
80070201-0301ffff
Sensor [SensorElementName]
has transitioned to critical from a less
severe state. (CPU 1 OverTemp)
Explanation: This message is for the use case when
an implementation has detected a Sensor transitioned
to critical from less severe.
Internal Event: No
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow (front and rear of
the server), that the air baffles are in place and
65
Chapter 3. Diagnostics

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x idataplex dx360 m4 7913

Table of Contents