IBM System x iDataPlex dx360 M4 7912 Service Manual page 160

Problem determination
Table of Contents

Advertisement

816f010c-2581ffff • 816f0125-0b01ffff
816f010c-2581ffff
Uncorrectable error recovery
detected for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (All
DIMMS)
Explanation: This message is for the use case when
an implementation has detected a Memory
uncorrectable error recovery.
Internal Event: No
Severity: Info
Alert Category: Critical - Memory
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0139
SNMP Trap ID: 41
Automatically notify Support: No
User response: No action; information only. One of
the DIMMs :
816f010f-2201ffff
The System
[ComputerSystemElementName] has
recovered from a firmware hang.
(Firmware Error)
Explanation: This message is for the use case when
an implementation has recovered from a System
Firmware Hang.
Internal Event: No
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0187
SNMP Trap ID: 50
Automatically notify Support: No
User response: No action; information only.
816f0113-0301ffff
System
[ComputerSystemElementName] has
recovered from a bus timeout. (CPU 1
PECI)
Explanation: This message is for the use case when
an implemenation has detected that a system has
recovered from a Bus Timeout.
Internal Event: No
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0225
142
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
(Trained technician only) Replace microprocessor n
(see Removing a microprocessor and heat sink and
Replacing a microprocessor and heat sink).
2.
If the problem persists and there is no other CPU
with the same error indication, replace the system
board.
3.
(Trained technician only) Replace the system board
(see Removing the system board and Replacing the
system board). (n = microprocessor number)
816f0113-0302ffff
System
[ComputerSystemElementName] has
recovered from a bus timeout. (CPU 2
PECI)
Explanation: This message is for the use case when
an implemenation has detected that a system has
recovered from a Bus Timeout.
Internal Event: No
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0225
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
(Trained technician only) Replace microprocessor n
(see Removing a microprocessor and heat sink and
Replacing a microprocessor and heat sink).
2.
If the problem persists and there is no other CPU
with the same error indication, replace the system
board.
3.
(Trained technician only) Replace the system board
(see Removing the system board and Replacing the
system board). (n = microprocessor number)
816f0125-0b01ffff
[ManagedElementName]
detected as present. (PCI Riser 1)
Explanation: This message is for the use case when
an implementation has detected a Managed Element is
now Present.
Internal Event: No
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0390
SNMP Trap ID: