IBM System x iDataPlex dx360 M4 7912 Service Manual page 219

Problem determination
Table of Contents

Advertisement

Reviewed: 09/03/2012
516-800-000 ELXUCNA: NIC MAC LoopBackTest
Aborted
Explanation: Loopback testing at the MAC layer was
canceled.
Internal Event: No
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
Date Message Added: 09/03/2012
Reviewed: 09/03/2012
516-801-000 ELXUCNA: NIC PHY LoopBackTest
Aborted
Explanation: Loopback testing at the physical layer
was canceled.
Internal Event: No
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
Date Message Added: 09/03/2012
Reviewed: 09/03/2012
516-802-000 ELXUCNA: ELXUCNA: NIC
LED(Beacon)Test Aborted
Explanation: Verification of status LEDs was
canceled.
Internal Event: No
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
Date Message Added: 09/03/2012
Reviewed: 09/03/2012
516-900-000 ELXUCNA: NIC MAC LoopBackTest
Failed
Explanation: A failure was detected during the
loopback test at the MAC layer.
Internal Event: No
Severity: Error
516-800-000 • 516-902-000
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check component firmware level and upgrade if
necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Date Message Added: 09/03/2012
Reviewed: 09/03/2012
516-901-000 ELXUCNA: NIC PHY LoopBackTest
Failed
Explanation: A failure was detected during the
loopback test at the physical layer.
Internal Event: No
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check component firmware level and upgrade if
necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Date Message Added: 09/03/2012
Reviewed: 09/03/2012
516-902-000 ELXUCNA: ELXUCNA: NIC
LED(Beacon)Test Failed
Explanation: A failure was detected while verifying
operation of the status LEDs.
Internal Event: No
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
201