816f000f-2201ffff • 816f0021-3001ffff
Internal Event: No
Severity: Info
Alert Category: System - Power On
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0107
SNMP Trap ID: 24
Automatically notify Support: No
User response: No action; information only.
816f000f-2201ffff
The System
[ComputerSystemElementName] has
detected a POST Error deassertion.
(ABR Status)
Explanation: This message is for the use case when
an implementation has detected that Post Error has
deasserted.
Internal Event: No
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0185
SNMP Trap ID: 50
Automatically notify Support: No
User response: No action; information only. Firmware
Error : Sys Boot Status :
816f0013-1701ffff
System
[ComputerSystemElementName] has
recovered from a diagnostic interrupt.
(NMI State)
Explanation: This message is for the use case when
an implementation has detected a recovery from a Front
Panel NMI / Diagnostic Interrupt
Internal Event: No
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0223
SNMP Trap ID: 50
Automatically notify Support: No
User response: No action; information only.
136
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
816f0021-2201ffff
Fault condition removed on slot
[PhysicalConnectorElementName] on
system
[ComputerSystemElementName]. (No
Op ROM Space)
Explanation: This message is for the use case when
an implementation has detected a Fault condition in a
slot has been removed.
Internal Event: No
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0331
SNMP Trap ID: 50
Automatically notify Support: No
User response: No action; information only.
816f0021-2582ffff
Fault condition removed on slot
[PhysicalConnectorElementName] on
system
[ComputerSystemElementName]. (All
PCI Error)
Explanation: This message is for the use case when
an implementation has detected a Fault condition in a
slot has been removed.
Internal Event: No
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0331
SNMP Trap ID: 50
Automatically notify Support: No
User response: No action; information only. One of
PCI Error :
816f0021-3001ffff
Fault condition removed on slot
[PhysicalConnectorElementName] on
system
[ComputerSystemElementName]. (Mezz
Error)
Explanation: This message is for the use case when
an implementation has detected a Fault condition in a
slot has been removed.
Internal Event: No
Severity: Info
Alert Category: Critical - Other
Serviceable: No