IBM System x iDataPlex dx360 M4 7912 Service Manual page 42

Problem determination
Table of Contents

Advertisement

S.3030007 • S.3108007
S.3030007
[S.3030007] A firmware fault has been
detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected,
System halted
Severity: Error
User response: Complete the following steps:
1.
Check IBM support site for an applicable service
bulletin or firmware update that applies to this error.
2.
Reflash UEFI image.
3.
(Trained service technician only) Replace the
system board.
S.3040007
[S.3040007] A firmware fault has been
detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected,
System halted
Severity: Error
User response: Complete the following steps:
1.
Check IBM support site for an applicable service
bulletin or firmware update that applies to this error.
2.
Reflash UEFI image.
3.
(Trained service technician only) Replace the
system board.
S.3050007
[S.3050007] A firmware fault has been
detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected,
System halted
Severity: Error
User response: Complete the following steps:
1.
Check IBM support site for an applicable service
bulletin or firmware update that applies to this error.
2.
Reflash UEFI image.
3.
(Trained service technician only) Replace the
system board.
S.3058004
[S.3058004] A Three Strike boot failure
has occurred. The system has booted
with default UEFI settings.
Explanation: POST failure has occurred! System
booted with default settings.
Severity: Error
User response: Complete the following steps:
1.
This event resets UEFI to the default settings for
the next boot. If successful, user is forced into F1
setup. Original UEFI settings are still present.
2.
If User did not intentionally trigger the reboots,
check logs for probable cause.
24
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
3.
Undo recent system changes (settings or devices
added). If not recent system changes, remove all
options then remove CMOS battery for 30 seconds
to clear CMOS contents. Verify that the system
boots. Then, re-install options one at a time to
locate the problem.
4.
Check IBM support site for an applicable service
bulletin or firmware update that applies to this error.
5.
Reflash UEFI firmware.
6.
Remove and re-install CMOS battery for 30
seconds to clear CMOS contents
7.
(Trained service technician only) Replace the
system board.
S.3060007
[S.3060007] A firmware fault has been
detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected,
System halted
Severity: Error
User response: Complete the following steps:
1.
Check IBM support site for an applicable service
bulletin or firmware update that applies to this error.
2.
Reflash UEFI image.
3.
(Trained service technician only) Replace the
system board.
S.3070007
[S.3070007] A firmware fault has been
detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected,
System halted
Severity: Error
User response: Complete the following steps:
1.
Check IBM support site for an applicable service
bulletin or firmware update that applies to this error.
2.
Reflash UEFI image.
3.
(Trained service technician only) Replace the
system board.
S.3108007
[S.3108007 ] The default system
settings have been restored.
Explanation: System Configuration Restored to
Defaults
Severity: Error
User response: Complete the following steps:
1.
Check IBM support site for an applicable service
bulletin or firmware update that applies to this error.