IBM System x iDataPlex dx360 M4 7912 Service Manual page 117

Problem determination
Table of Contents

Advertisement

User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory
fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions
for that error event and restart the server.
3.
Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory event. If no memory fault is recorded in the
logs and no DIMM connector error LED is lit, you
can re-enable the DIMM through the Setup utility or
the Advanced Settings Utility (ASU).
806f040c-200bffff
[PhysicalMemoryElementName]
Disabled on Subsystem
[MemoryElementName]. (DIMM 11)
Explanation: This message is for the use case when
an implementation has detected that Memory has been
Disabled.
Internal Event: No
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory
fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions
for that error event and restart the server.
3.
Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory event. If no memory fault is recorded in the
logs and no DIMM connector error LED is lit, you
can re-enable the DIMM through the Setup utility or
the Advanced Settings Utility (ASU).
806f040c-200cffff
[PhysicalMemoryElementName]
Disabled on Subsystem
[MemoryElementName]. (DIMM 12)
Explanation: This message is for the use case when
an implementation has detected that Memory has been
Disabled.
Internal Event: No
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
806f040c-200bffff • 806f040c-200effff
SNMP Trap ID:
Automatically notify Support: No
User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory
fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions
for that error event and restart the server.
3.
Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory event. If no memory fault is recorded in the
logs and no DIMM connector error LED is lit, you
can re-enable the DIMM through the Setup utility or
the Advanced Settings Utility (ASU).
806f040c-200dffff
[PhysicalMemoryElementName]
Disabled on Subsystem
[MemoryElementName]. (DIMM 13)
Explanation: This message is for the use case when
an implementation has detected that Memory has been
Disabled.
Internal Event: No
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory
fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions
for that error event and restart the server.
3.
Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory event. If no memory fault is recorded in the
logs and no DIMM connector error LED is lit, you
can re-enable the DIMM through the Setup utility or
the Advanced Settings Utility (ASU).
806f040c-200effff
[PhysicalMemoryElementName]
Disabled on Subsystem
[MemoryElementName]. (DIMM 14)
Explanation: This message is for the use case when
an implementation has detected that Memory has been
Disabled.
Internal Event: No
Severity: Info
Alert Category: System - Other