Set Summertime Date; Set Summertime Recurring - Enterasys SecureStack C2 C2G170-24 Configuration Manual

Stackable switches
Hide thumbs Also See for SecureStack C2 C2G170-24:
Table of Contents

Advertisement

set summertime date

Use this command to configure specific dates to start and stop daylight savings time. These 
settings will be non‐recurring and will have to be reset annually.
Syntax
set summertime date start_month start_date start_year start_hr_min end_month
end_date end_year end_hr_min [offset_minutes]
Parameters
start_month 
start_date 
start_year 
start_hr_min
end_month
end_date
end_year
end_hr_min
offset_minutes
Defaults
If an offset is not specified, none will be applied.
Mode
Switch command, read‐write.
Example
This example shows how to set a daylight savings time start date of April 4, 2004 at 2 a.m. and an 
ending date of October 31, 2004 at 2 a.m. with an offset time of one hour:
C2(su)->set summertime date April 4 2004 02:00 October 31 2004 02:00 60

set summertime recurring

Use this command to configure recurring daylight savings time settings. These settings will start 
and stop daylight savings time at the specified day of the month and hour each year and will not 
have to be reset annually.
Syntax
set summertime recurring start_week start_day start_month start_hr_min end_week
end_day end_month end_hr_min [offset_minutes]
Specifies the month of the year to start daylight savings time.
Specifies the day of the month to start daylight savings time. 
Specifies the year to start daylight savings time.
Specifies the time of day to start daylight savings time. Format is hh:mm.
Specifies the month of the year to end daylight savings time.
Specifies the day of the month to end daylight savings time. 
Specifies the year to end daylight savings time.
Specifies the time of day to end daylight savings time. Format is hh:mm.
(Optional) Specifies the amount of time in minutes to offset daylight 
savings time from the non‐daylight savings time system setting. Valid 
values are 1 ‐ 1440.
set summertime date
SecureStack C2 Configuration Guide 3-21

Advertisement

Table of Contents
loading

This manual is also suitable for:

C2h124-24Securestack c2

Table of Contents