Mode
Switch command, read‐only.
Example
This example shows how to display the edge port status for ge.3.2:
C2(su)->show spantree adminedge port
ge.
Port

set spantree adminedge

Use this command to set the edge port administrative status on a Spanning Tree port.
Syntax
set spantree adminedge port-string {true | false}
Parameters
port‐string
true | false
Defaults
None.
Mode
Switch command, read‐write.
Usage
The default behavior of the edge port administrative status begins with the value set to false 
initially after the device is powered up. If a Spanning Tree BDPU is not received on the port within 
a few seconds, the status setting changes to true. 
Example
This example shows how to set ge.1.11 as an edge port:
C2(su)->set spantree adminedge

clear spantree adminedge

Use this command to reset a Spanning Tree port to non‐edge status.
Syntax
clear spantree adminedge port-string
3.2 has a Port Admin Edge of Edge-Port
Specifies the edge port. For a detailed description of possible port‐string 
values, refer to "Port String Syntax Used in the CLI" on page 7‐2.
Enables (true) or disables (false) the specified port as a Spanning Tree edge 
port.
ge.
3.2
ge.
1.11 true
set spantree adminedge