Set Linkflap Interval; Set Linkflap Action - Enterasys SecureStack C2 C2G170-24 Configuration Manual

Stackable switches
Hide thumbs Also See for SecureStack C2 C2G170-24:
Table of Contents

Advertisement

set linkflap interval

Mode
Switch command, read‐write.
Example
This example shows how to enable the link trap monitoring on all ports.
C2(rw)->set linkflap portstate enable
set linkflap interval
Use this command to set the time interval (in seconds) for accumulating link down transitions.
Syntax
set linkflap interval port-string interval-value
Parameters
port‐string
interval‐value
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to set the link flap interval on port ge.1.4 to 1000 seconds.
C2(rw)->set linkflap interval

set linkflap action

Use this command to set reactions to a link flap violation. 
Syntax
set linkflap action port-string {disableInterface | gensyslogentry | gentrap |
all}
Parameters
port‐string
disableInterface
gensyslogentry
gentrap
all
7-26 Port Configuration
Specifies the port(s) on which to set the link flap interval. 
Specifies an interval in seconds. A value of 0 will set the interval to 
forever.
ge.
1.4 1000
Specifies the port(s) on which to set the link flap action. 
Sets the reaction as disabling the interface. 
Sets the reaction as generating a syslog entry.
Sets the reaction as generating an SNMP trap.
Sets the reaction as all of the above. 