leaveall timer‐
value
port‐string
Defaults
None.
Mode
Switch command, read‐write.
Usage
The setting of these timers is critical and should only be changed by personnel familiar with the 
802.1Q standards documentation, which is not supplied with this device.
Examples
This example shows how to set the GARP join timer value to 100 centiseconds for all ports:
C2(su)->set garp timer join 100 *.*.*
This example shows how to set the leave timer value to 300 centiseconds for all ports:
C2(su)->set garp timer leave 300 *.*.*
This example shows how to set the leaveall timer value to 20000 centiseconds for all ports:
C2(su)->set garp timer leaveall 20000 *.*.*
Sets the GARP leaveall timer in centiseconds (Refer to 802.1Q standard.)
Specifies the port(s) on which to configure GARP timer settings. For a 
detailed description of possible port‐string values, refer to "Port String 
Syntax Used in the CLI" on page 7‐2.
SecureStack C2 Configuration Guide 10-25
set garp timer