Show Spantree Legacypathcost; Set Spantree Legacypathcost - Enterasys SecureStack C2 C2G170-24 Configuration Manual

Stackable switches
Hide thumbs Also See for SecureStack C2 C2G170-24:
Table of Contents

Advertisement

show spantree legacypathcost

Use this command to display the default Spanning Tree path cost setting.
Syntax
show spantree legacypathcost
Parameters
None.
Defaults
None.
Mode
Switch command, read‐only.
Example
This example shows how to display the default Spanning Tree path cost setting.
C2(su)->show spantree legacypathcost
Legacy Path Cost is disabled.

set spantree legacypathcost

Use this command to enable or disable legacy (802.1D) path cost values.
Syntax
set spantree legacypathcost {disable | enable}
Parameters
disable
enable
Defaults
None.
Mode
Switch command, read‐write.
Usage
By default, legacy path cost is disabled. Enabling the device to calculate legacy path costs affects 
the range of valid values that can be entered in the set spantree adminpathcost command.
Example
This example shows how to set the default path cost values to 802.1D.
C2(rw)->set spantree legacypathcost enable
Use 802.1t2001 values to calculate path cost.
Use 802.1d1998 values to calculate path cost.
show spantree legacypathcost
SecureStack C2 Configuration Guide 9-31