Set Rmon Capture - Enterasys SecureStack C2 C2G170-24 Configuration Manual

Stackable switches
Hide thumbs Also See for SecureStack C2 C2G170-24:
Table of Contents

Advertisement

Owner
captureEntry= 1
--------------------------------------------
Pkt ID
Pkt Length
Data:
00 00 5e 00 01 01 00 01 f4 00 7d ce 08 00 45 00
00 4b b4 b9 00 00 40 11 32 5c 0a 15 43 05 86 8d
bf e5 00 a1 0e 2b 00 37 cf ca 30 2d 02 01 00 04
06 70 75 62 6c 69 63 a2 20 02 02 0c 92 02 01 00
02 01 00 30 14 30 12 06 0d 2b 06 01 02 01 10 07
01 01 0b 81 fd 1c 02 01 01 00 11 0b 00

set rmon capture

Use this command to configure an RMON capture entry.
Syntax
set rmon capture index {channel [action {lock}] [slice slice] [loadsize loadsize]
[offset offset] [asksize asksize] [owner owner]}
Parameters
index
channel
action lock 
slice slice
loadsize loadsize
offset offset
asksize asksize
owner
Defaults
If not specified, action defaults to lock.
If not specified, offset defaults to 0.
If not specified, asksize defaults to ‐1 (which will request as many octets as possible).
If slice is not specified, 1518 will be applied.
If loadsize is not specified, 100 will be applied.
If owner is not specified, it will be set to monitor.
monitor
Buff.control= 28062
9
Pkt time
93
Pkt status
Specifies a buffer control entry.
Specifies the channel to which this capture entry will be applied.
(Optional) Specifies the action of the buffer when it is full as:
lock ‐ Packets will cease to be accepted
(Optional) Specifies the maximum octets from each packet to be saved in 
a buffer. Currently, the only value allowed is 1518.
(Optional) Specifies the maximum octets from each packet to be 
downloaded from the buffer. The default is 100.
(Optional) Specifies the first octet from each packet that will be retrieved.
(Optional) Specifies the requested maximum octets to be saved in this 
buffer. Currently, the only value accepted is ‐1, which requests as many 
octets as possible.
(Optional) Specifies the name of the entity that configured this entry.
1 days 0 hours 51 minutes 15 seconds
0
SecureStack C2 Configuration Guide 15-23
set rmon capture

Advertisement

Table of Contents
loading

This manual is also suitable for:

C2h124-24Securestack c2

Table of Contents