XSCF>   setpparparam -p 0 -s bootscript "setenv auto-boot? false"
6.
Power on the physical partition requiring maintenance.
For details, see
7.
The ok prompt appears.
8.
Enable the RAID volume to check the status.
For details, see "14.2.11 Re-enabling a hardware RAID volume" in the Fujitsu
M10/SPARC M10 Systems System Operation and Administration Guide.
9.
Execute the setpparparam command to activate the Autoboot function of the
control domain.
In the following example, PPAR-ID 0 is set for Auto boot.
XSCF>   setpparparam -p 0 -s bootscript "setenv auto-boot? true"
10. Close the rack door.
7.8.3

System-stopped maintenance

When the system is configured without a hardware RAID
1.
Connect all the power cords to the PSU backplane unit of the chassis
requiring maintenance.
For details, see
Note - In the case of a dual power feed, connect the power cords in their original positions by
referring to the record that you made before the start of maintenance.
2.
Return to the operation of the XSCF firmware replacefru command to confirm
that the chassis has been incorporated into the system.
For details, see
the
For a single-chassis configuration, you do not have to incorporate the chassis.
Proceed to step 4.
3.
Execute the diagxbu command to diagnose the crossbar cables.
Diagnosis is performed when the system board of the chassis connected with the
crossbar cables is not incorporated into the physical partition, or when the
physical partition into which the chassis is incorporated is powered off.
The example below specifies the following:
00: BB-ID of the chassis to start the diagnosis
01: BB-ID of the destination where the chassis to start the diagnosis is connected
(You can specify one or more of these.)
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014
162
"6.3 Powering On the Physical Partition Requiring
"6.5.1 Installing the power
"6.1.1 Incorporating an FRU of the SPARC M10-4/M10-4S into
system."
 
cord."
Maintenance."

Advertisement

Table of Contents
loading

This manual is also suitable for:

M10-4sSparc m10-4Sparc m10-4s

Table of Contents