Note - Check that the XSCF BB control cables are correctly connected and secure.
Note - After connecting the XSCF BB control cable, use the hook-and-loop fastener to bundle
the cables together and secure them to the rear cable support.
26.6
Restoring the System
This section describes the procedure for restoring the system after installing the XSCF
BB control cables. The restoration procedure differs depending on the maintenance
type as follows:
Active/Hot maintenance
Active/Cold maintenance
Inactive/Cold maintenance
System-stopped maintenance
26.6.1
Active/Hot maintenance
1.
Disconnect and then connect the XSCF unit.
2.
Return to the replacefru command operation of the XSCF firmware to confirm
that the XSCF unit of the crossbar box has been incorporated into the system.
For details, see
3.
Execute the showstatus command to confirm that the FRU is operating
normally after the completion of maintenance.
XSCF>   showstatus
4.
Execute the showhardconf command to check the hardware configuration
and the status of each component.
XSCF>   showhardconf
5.
Execute the switchscf command to switch the standby XSCF to the master
XSCF.
Execute the command if the chassis requiring maintenance has been switched to
the standby XSCF.
XSCF>   switchscf -t Active
6.
Close the rack door.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014
402
"6.1.2 Incorporating an FRU of the crossbar box into the
system."