Active/Hot Maintenance; Inactive/Hot Maintenance - Fujitsu M10-4 Service Manual

Hide thumbs Also See for M10-4:
Table of Contents

Advertisement

Active/Hot maintenance

Inactive/Hot maintenance

Inactive/Cold maintenance
System-stopped maintenance
10.6.1
Active/Hot maintenance
1.
Return to the operation of the XSCF firmware replacefru command to confirm
that the power supply unit has been incorporated into the system.
For details, see
the
2.
Execute the showstatus command to confirm that there is no problem with
the power supply unit after the completion of maintenance.
XSCF>   showstatus
3.
Execute the showhardconf command to check the hardware configuration
and the status of each component.
XSCF>   showhardconf
4.
Close the rack door.
10.6.2
Inactive/Hot maintenance
For a single-chassis configuration
1.
Log in to the XSCF shell.
2.
Return to the operation of the XSCF firmware replacefru command to confirm
that the power supply unit has been incorporated into the system.
For details, see
the
3.
Start the entire system.
For details, see
4.
Close the rack door.
For a building-block configuration
1.
Log in to the XSCF shell.
2.
Return to the operation of the XSCF firmware replacefru command to confirm
that the power supply unit has been incorporated into the system.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014
208
"6.1.1 Incorporating an FRU of the SPARC M10-4/M10-4S into
system."
"6.1.1 Incorporating an FRU of the SPARC M10-4/M10-4S into
system."
"6.4 Starting the Entire
System."