For details, see
27.3.2
Active/Cold maintenance
1.
Open the rack door.
2.
Log in to the XSCF shell.
3.
Execute the showlogs command to identify the component requiring
maintenance.
XSCF>   showlogs error
For details, see
4.
Confirm the hardware and software configurations.
For details, see
5.
Release the chassis connected to the XSCF DUAL control cable requiring
maintenance from the physical partition.
For details, see
6.
Execute the replacefru command to release the XSCF DUAL control cable
requiring maintenance from the system.
XSCF>   replacefru
For details, see
system."
7.
Remove all the power cords from the PSU backplane unit or power supply
unit of the chassis requiring maintenance.
For details, see
Note - In the case of a dual power feed, make a note of the locations of the power cords
before disconnecting them to ensure that they are reinstalled correctly.
27.3.3
Inactive/Cold maintenance
1.
Open the rack door.
2.
Log in to the XSCF shell.
3.
Execute the showlogs command to identify the component requiring
maintenance.
XSCF>   showlogs error
"5.1.2 Releasing an FRU of the crossbar box from the
"3.3.5 Checking log
information."
"4.2 Confirming the System
"5.2 Releasing a Chassis from the Physical
"5.1.1 Releasing an FRU of the SPARC M10-4/M10-4S from the
"5.5.2 Removing the power
Chapter 27 Maintaining the XSCF DUAL Control Cables
Configuration."
Partition."
cord."
system."
409

Advertisement

Table of Contents
loading

This manual is also suitable for:

M10-4sSparc m10-4Sparc m10-4s

Table of Contents