When the system is configured with a software RAID
See your software manual.
When the system is configured without either a hardware RAID or software
RAID
To replace or remove an internal disk, perform the procedure from step 2.
1.
Return to the operation of the cfgadm(1M) command of Oracle Solaris
super-user prompt and confirm that the number of internal disks has increased.
If you installed an internal disk, make note of the Ap_ID of the added disk. The
Ap_ID refers to a string such as "c4::dsk/c4t5000039428298FFEd0".
If you replaced or reduced an internal disk, you do not have to perform this step.
#   cfgadm -a
2.
Execute the cfgadm(1M) command to incorporate the internal disk requiring
maintenance into Oracle Solaris.
Enter the Ap_ID you noted in advance.
#   cfgadm -c configure  Ap_ID
3.
Execute the cfgadm(1M) command to confirm that the internal disk requiring
maintenance has been incorporated.
The incorporated internal disk is displayed as "configured."
#   cfgadm -a
4.
Close the rack door.
12.6.2
Active/hot maintenance (with DR)
1.
Execute the testsb command to confirm that the internal disk requiring
maintenance is recognized.
When you add the "-y" option to the testsb command, the system automatically
answers "y" (yes) in response to an inquiry.
The following example shows the diagnosis of system board 00-0.
XSCF>   testsb -v -y -p 00-0
During the diagnosis processing, the probe-scsi-all command of the OpenBoot
PROM is executed, and the result is displayed.
2.
Incorporate the chassis, in which the internal disk requiring maintenance is
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014