Fujitsu M10-4 Service Manual page 295

Hide thumbs Also See for M10-4:
Table of Contents

Advertisement

Note - In the case of a dual power feed, make a note of the locations of the power cords
before disconnecting them to ensure that they are reinstalled correctly.
14.3.2
Inactive/Cold maintenance
Note - The inactive/cold maintenance procedure for a single-chassis configuration is the same
as that for stopping the system.
1.
Open the rack door.
2.
Log in to the XSCF shell.
3.
Execute the showlogs command to identify the component requiring
maintenance.
XSCF>   showlogs error
For details, see
4.
Confirm the hardware and software configurations.
For details, see
5.
Power off the physical partition requiring maintenance.
For details, see
6.
Execute the replacefru command to release the chassis requiring maintenance
from the system.
XSCF>   replacefru
For details, see
system."
7.
Remove all the power cords from the PSU backplane unit of the chassis
requiring maintenance.
For details, see
Note - In the case of a dual power feed, make a note of the locations of the power cords
before disconnecting them to ensure that they are reinstalled correctly.
14.3.3
System-stopped maintenance
1.
Open the rack door.
2.
Log in to the XSCF shell.
"3.3.5 Checking log
information."
"4.2 Confirming the System
"5.3 Powering Off the Physical Partition Requiring
"5.1.1 Releasing an FRU of the SPARC M10-4/M10-4S from the
"5.5.2 Removing the power
Chapter 14 Maintaining the PSU Backplane Unit
Configuration."
Maintenance."
cord."
271

Advertisement

Table of Contents
loading

This manual is also suitable for:

M10-4sSparc m10-4Sparc m10-4s

Table of Contents