Fujitsu M10-4 Service Manual page 288

Hide thumbs Also See for M10-4:
Table of Contents

Advertisement

7.
Close the rack door.
13.7.2
Active/hot maintenance (with DR)
1.
Execute the testsb command to confirm that the PCIe card requiring
maintenance is recognized.
When you add the "-y" option to the testsb command, the system automatically
answers "y" (yes) in response to an inquiry.
The following example shows the diagnosis of system board 00-0.
XSCF>   testsb -v -y -s 00-0
During the diagnosis processing, the show-devs command of OpenBoot PROM
is executed, and the result is displayed.
2.
Incorporate into the physical partition the chassis in which the PCIe card
requiring maintenance is mounted.
For details, see
3.
Close the rack door.
13.7.3
Inactive/Hot maintenance
1.
Log in to the XSCF shell.
2.
Execute the testsb command to confirm that the PCIe card requiring
maintenance is recognized.
When you add the "-y" option to the testsb command, the system automatically
answers "y" (yes) in response to an inquiry.
The following example shows the diagnosis of system board 00-0.
XSCF>   testsb -v -y -s 00-0
3.
Power on the physical partition requiring maintenance.
For details, see
4.
Close the rack door.
13.7.4
System-stopped maintenance
1.
Log in to the XSCF shell.
2.
Execute the testsb command to confirm that the PCIe card requiring
maintenance is recognized.
When you add the "-y" option to the testsb command, the system automatically
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014
264
"6.2 Incorporating a Chassis into a Physical
"6.3 Powering On the Physical Partition Requiring
Partition."
Maintenance."

Advertisement

Table of Contents
loading

This manual is also suitable for:

M10-4sSparc m10-4Sparc m10-4s

Table of Contents